EN
17
How to proceed:
1. Screw the adapter onto the pump.
– Ensure that the O-ring is correctly seated.
2. Screw the unit onto the adapter.
– When fitting, ensure that the arrow on the cover and the outlet of the unit point in the di-
rection of the water flow.
3. Connect the unit to the downstream line.
NOTE
Ensure that all connection lines are completely leak-tight, as leaking lines can impair the function
of the system and lead to damage.
Use a suitable sealant to seal the threads of the lines and the connection to the pump.
Overtightening of plastic screw connections can lead to damage. Do not apply excessive force.