ONE-TIME DOMESTIC WATER HEATING FUNCTION
With this function the domestic water can be heated up at any time. The
function is automatically turned o󰀨 when domestic water has reached
the set temperature or latest after one hour.
The function can be activated by pressing the key .
Set domestic water temperature
Display for one-time domestic water
heating function
The temperature set for domestic water can be changed by pressing
the keys and . Change the setting while the value is ashing. By
pressing the key again, you return to the basic display.
The one-time domestic water function can be turned o󰀨 before expirati-
on by pressing .
FIREPLACE FUNCTION
The replace function ensures that the actual room temperature does
not e󰀨ect the heating control. This function is to be used when the re-
place is on. This prevents the system from reducing the temperature in
other rooms due to increase of temperature in the living room.
The function can be activated by pressing the key for 10 seconds.
Operation of the replace function is indicated by the ashing symbol .
The replace function is active for the time set under parameter S1.13.
After expiration of the set time, it will remain being active until until the
measured room temperature is higher than the set room temperature.