P1.4
DISPLAY ILLUMINATION OPERATION MODE
This setting determines the type of operation of the
display illumination.
The following settings are available: 0 - no display
illumination.
1- The display has maximum brightness when
entering settings to the room unit. After a period
of time the display illumination is reduced to its
minimum value.
2- Same as 1, but display illumination is adapted to
the amount of light in the room.
3- Same as 2, but room unit display is completely
turned off in standby mode during night temperature
interval between 6pm and 6am.
0 ÷ 3 (2)
P1.5
MINIMUM SCREEN ILLUMINATION
This setting determines minimum display illumina-
tion.
0 ÷ 100 % (5)
P1.6
MAXIMUM SCREEN ILLUMINATION
This setting determines maximum display illumina-
tion.
0 ÷ 100 % (80)
P1.7
DISPLAY CONTRAST
This setting determines display contrast.
1 ÷ 8 (6)
P1.8
SOUND
This setting determines when sound is activated
0 - never
1 - keys
2 - keys and warnings
3 - keys, warnings,
and notications
P1.9
DISPLAYING WARNINGS AND MESSAGES
This setting determines whether warnings and
notications are displayed.
0 - no display
1 - warnings
2 - warnings and
notications
P1.10
BASIC DISPLAY
This setting determines which information will be
displayed on the basic display.
1 - room temp.
2 - auxilliary temp.
3 - d. h. w. temp.
4 - humidity
5 - air pressure
6 - auxiliary sensor
11 - T1 controller sensor
...