EasyManua.ls Logo

Ohmeda Giraffe OmniBed - User Manual

Ohmeda Giraffe OmniBed
54 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Giraffe
TM
OmniBed
TM
Operators Manual
Question and Answer IconNeed help?

Do you have a question about the Ohmeda Giraffe OmniBed and is the answer not in the manual?

Summary

User Responsibility

General Information

Incubator;Warmer Operating Modes

Explains how the OmniBed functions as both an incubator and a radiant warmer.

Control Modes

Details the different operational modes (Air, Baby, Manual) for temperature control.

Controls and Displays

Identifies and describes the physical controls and screen elements of the device.

Temperature Regulation

Explains how to select and adjust temperature settings for various modes.

Incubator Operation

Covers the specific procedures and settings for using the OmniBed as an incubator.

Air Control Mode

Details settings and display for incubator operation using air temperature control.

Baby Control Mode (Incubator)

Details settings and display for incubator operation using baby's skin temperature.

Boost Air Curtain

Explains how to increase fan speed for improved thermal performance during open door access.

Warmer Operation

Covers the specific procedures and settings for using the OmniBed as a warmer.

Manual Control Mode

Details settings for warmer operation using manual radiant heater power control.

Baby Control Mode (Warmer)

Details settings for warmer operation using baby's skin temperature control.

Operating with Two Temperature Probes

Explains how to use dual probes for co-bedding or monitoring multiple sites.

Operating Mode Transition

Describes how the OmniBed automatically switches modes when the canopy position changes.

Accessory Options

Introduces the various optional features and how to access them via the menu.

Timer

Details the function and operation of the unit's built-in timer.

Trend

Explains how to view historical temperature and mode data graphically.

Comfort Zone

Describes the reference screen for calculating suggested infant temperature ranges.

Setup;Customize

Covers settings for temperature units, alarms, and other device configurations.

Scale

Explains the operation and features of the integrated in-bed scale.

Servo-Humidity

Details how to set and monitor humidity levels within the infant compartment.

Alarms

Provides information on how alarms are indicated and managed on the unit.

High Air Temperature

Describes the conditions and actions for the high air temperature alarm.

Low Air Temperature

Describes the conditions and actions for the low air temperature alarm.

Baby Hot - Check Probe 1

Explains the alarm for a baby's temperature being too high.

Baby Cold - Check Probe 1

Explains the alarm for a baby's temperature being too low.

Air Temperature Greater Than... Alarms

Groups alarms related to excessive air temperatures in the compartment.

Air Temperature >38°C

Details the alarm for air temperature exceeding 38°C.

Air Temperature >40°C

Details the alarm for air temperature exceeding 40°C.

Disconnected Baby Probe 1

Explains the alarm triggered when the baby probe is unplugged.

Fan Failure

Describes the alarm indicating a fan malfunction or lack of airflow.

Fan Always in High Speed

Explains the alarm for the fan operating at high speed due to sensor malfunction.

Air Probe Disconnect

Details the alarm for the disconnection of the air temperature probe.

Air Probe Failure

Explains the alarm for a malfunctioning air temperature probe.

In Transition- Heat Off

Describes the alarm when the canopy movement is interrupted, shutting off heat.

Check Baby

Explains the alarm related to the radiant heater running at high power for an extended period.

System Failure

Details the critical alarm indicating a system malfunction or electrical failure.

Bad Membrane Switch

Explains the alarm for a failure in the control panel's membrane switches.

Power Failure

Describes the alarm and indicator for loss of electrical power.

Service Alarms

Groups alarms that indicate a need for repair but may allow continued use in a different mode.

Option Alarms

Lists and describes alarms related to optional features like the humidifier and scale.

Humidifier Alarms

Details alarms associated with the humidifier's operation and water level.

Scale Alarms

Explains alarms related to the scale's maximum weight limit and system failures.

Alarm Table

Presents a comprehensive table detailing all alarms, activation criteria, and audio signals.

Cable Connections and Mechanical Controls

Illustrates and identifies the physical connections and mechanical controls on the unit.

Preoperative Checkout Procedure

Setup

Instructions for preparing the OmniBed for use after shipping, including canopy lock release.

Mechanical Checks

Steps to inspect the physical components of the OmniBed for proper condition and function.

Controller Checks

Procedures to verify the operation of the control panel, displays, and basic functions.

Accessory Checks

Guidelines for verifying the secure mounting and proper operation of accessories.

Operating the OmniBed

Basic Operating Procedure

Essential steps and safety precautions for initial patient setup and operation.

Operation as an Incubator

Detailed steps for using the OmniBed in incubator mode, including preheating and probe attachment.

Operation as a Warmer

Detailed steps for using the OmniBed in warmer mode, including preheating and power settings.

Attaching the Skin Temperature Probe

Instructions on correctly applying the skin temperature probe for accurate readings.

Additional Operating Procedures

Covers various procedures for accessing the patient and adjusting the bed.

Accessing the Baby

Steps for opening portholes, side doors, and mattress tray for patient access.

Raising the Canopy

Instructions on how to raise and lower the unit's canopy for patient access.

Raising and Lowering the Bed

How to adjust the bed height using the foot pedals for caregiver convenience.

Tilting the Bed

Explains how to tilt the bed for specific patient positioning needs.

Using the X-ray Tray

Instructions for using the integrated tray for X-ray procedures.

Administering Oxygen

Safety precautions and procedures for administering oxygen within the compartment.

Installing Wristlets

Guidance on installing the porthole wristlets for patient restraint.

Using the Humidifier

Steps for filling, operating, and removing the humidifier reservoir.

ThermaLink Option

Information on connecting the OmniBed to external monitoring systems.

Using the Serial Data Interface

Details on connecting and using the RS-232 data output for monitoring.

Using the Nurse Call System Interface

How to connect the OmniBed to a remote nurse call system.

Nurse Call Checkout

Steps to verify the proper function of the Nurse Call integration.

Using the In-Bed Scale

Instructions for installing and using the integrated weighing scale.

Scale Installation

Steps for correctly fitting the scale platform and connecting the cable.

Weighing Procedure

Guidance on how to accurately weigh a patient using the in-bed scale.

Mounting Accessories

Procedures for attaching various accessories to the OmniBed's rail system.

Gas Cylinder Holder

Instructions for mounting the gas cylinder holder onto the unit.

Tubing Management Arm

Guidance on mounting the arm for organizing patient tubing.

Oscillator Port Cover

Instructions for using the cover to close an oscillator port.

Maintaining the OmniBed

Repair Policy

Outlines the procedures and conditions for warranty repair and service.

Maintenance Schedule

Provides a schedule for regular operator and service maintenance tasks.

Operator Maintenance

Lists routine cleaning and filter replacement tasks for users.

Service Maintenance

Lists periodic tasks like electrical safety checks and calibration for trained personnel.

Disassembling for Cleaning

Step-by-step instructions for disassembling the unit for thorough cleaning.

Cleaning and Disinfecting Components

Detailed procedures for cleaning and disinfecting specific parts like the humidifier and probes.

Humidifier Cleaning

Instructions for cleaning and disinfecting the humidifier reservoir.

Patient Probe Cleaning

Guidance on cleaning and disinfecting reusable temperature probes.

Cleaning Other Components

Instructions for cleaning the remaining components of the OmniBed.

Accessories

Appendix

Specifications

Details technical specifications including power, standards, environment, and user settings.

Operating Environment

Specifies the recommended temperature and humidity ranges for operation.

Storage Conditions

Specifies the recommended temperature, humidity, and pressure for storage.

User Control Settings

Lists the adjustable parameters for patient temperature, air control, and humidity.

Appendix Alarms

Summarizes the types of alarms and their activation criteria.

Performance

Presents performance data and metrics for the OmniBed's various systems.

System Performance

Details performance metrics for control accuracy, variability, warm-up time, and air velocity.

Humidity Performance

Provides performance data for the servo-humidity control and manual humidity settings.

Weight Scale Performance

Lists performance specifications for the integrated weight scale, including range and accuracy.

Mechanical Specifications

Provides physical dimensions and weight of the OmniBed in different configurations.

Accessory Load Limits

Lists maximum load capacities for various accessory mounting points.

Warranty

Ohmeda Giraffe OmniBed Specifications

General IconGeneral
BrandOhmeda
ModelGiraffe OmniBed
CategoryMedical Equipment
LanguageEnglish