EasyManua.ls Logo

OJ Electronics UTCG-9991 - Reset to Factory Setting; Failure Codes; Technical Data

OJ Electronics UTCG-9991
6 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Press the pin button for 3 secs. and the thermostat returns to factory settings. Time,
day and scale for time (12h, 24h) and temperature (˚F, ˚C) read-out are also reset and
must be set according to “Setting the thermostat into operation”.
5. Reset to factory setting
4-event time and temperature
Day 1-5
06:00
Time With floor sensor Built-in sensor
08:00
16:00
22:30
08:00
23:00
5:24-event sequence
131˚F / 41˚F
24 H / ˚F
ON
Hi-Low temp.
Scale
Adaptive control
Day 6-7
77˚F / 25˚C 68˚F / 20˚C
68˚F / 20˚C 59˚F / 15˚C
81˚F / 27˚C 72˚F / 22˚C
68˚F / 20˚C 59˚F / 15˚C
81˚F / 27˚C 72˚F / 22˚C
68˚F / 20˚C 59˚F / 15˚C
6. Failure codes
E0 = Internal failure, replace thermostat
E1 = Built-in sensor short-circuit or disconnected,
replace thermostat
E2 = External sensor short-circuit or disconnected
7. Technical data
Supply: . . . . . . . . . . . . . . . . . . 120/240 Vac 50/60 Hz
Load: . . . . . . . . . . . . 16A maximum (resistive load)
Power: . . . . . . . . . . . . . . . . . . . . 1.920 W at 120 Vac
3.840 W at 240 Vac
GFCI: . . . . . . . . . . . . . . . . . Class A (5 mA trip level)
Temperature range: . . . . +5 to +40°C, +40 to +104˚F
Amb. Temperature range:
Thermostat: . . . . . . . . . . . 0 to +40°C, +32 to +104˚F
GFCI: . . . . . . . . . . . . . -35 to +65°C, -31 to +149˚F
OJ ELECTRONICS A/S
Stenager 13B · DK-6400 Sønderborg
Tel. +45 73 12 13 14 · Fax +45 73 12 13 13
www.oj.dk
Factory settings