EasyManua.ls Logo

OK International DX-200 - User Manual

Default Icon
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
OK International
DX-200 / 215
Precision Dispensers
User Guide
English, Simplified Chinese, Traditional Chinese and Korean Version
Copyright © OK International
DX-200 / 215
精密点胶机
用户指南
DX-200 / 215
精密點膠機
使用者指南
DX-200 / 215
정밀 디스펜서
사용설명서
2
CONTENTS
Page Number
1 Safety....................................................................................................2 - 3
2 Symbol Definitions...............................................................................3
3 Specifications .......................................................................................3
4 Features ................................................................................................4
5 Connecting the Unit..............................................................................5
6 Setup Instructions.................................................................................5 - 6
7 Operational Diagram ............................................................................6
8 Troubleshooting ...................................................................................7
9 Maintenance .........................................................................................8
10 Spare Parts and Accessories .................................................................8
11 Warranty...............................................................................................8
12 I/O Configuration and End of Cycle Switch ........................................8
1 SAFETY
1.1 Intended Use:
WARNING: Use of this equipment in ways other than those described in this User
Guide may result in injury to persons or damage to property. Use this equipment
only as described in this User Guide.
OK International cannot be responsible for injuries or damages resulting from
unintended applications of its equipment. Unintended uses may result form taking
the following actions:
Making changes to equipment that has not been recommended in the User
Guide
Using incompatible or damaged replacement parts
Using unapproved accessories or auxiliary equipment
1.2 Safety Precautions:
Do not operate this unit in excess of maximum ratings/settings
Always wear appropriate personal protective clothing or apparel
Use only the following power adaptor models: PSA15R-240P(ZJ) or
PW118RA2403B01, PW118RA2403H01, PW118RA2403M01,
PW118RA2403G01
Care must be taken to prevent the ingress of corrosive or flammable fluid back
into the unit. If corrosive or flammable fluids are used, an inline filter (881-
000-000) must be installed on the dispenser to help prevent the fluids from
being sucked back into the unit
The fluid being dispensed may be toxic and/or hazardous. Refer to Material
Safety Data Sheet for proper handling and safety precautions

Questions and Answers

  • C
    calvin29Jul 26, 2025
    What to do if my OK International DX-200 Dispenser system will not actuate?
    • B
      Brenda OlsonJul 26, 2025
      If your OK International Dispenser system isn't actuating, there might be a few reasons: * The foot switch might not be correctly plugged in – check its connection. * The foot switch itself could be defective, needing repair or replacement. * There could be a broken wire or loose connection inside the unit. In this case, unplug the power cord and disconnect the air supply, then remove the cover to inspect for any issues. * A solenoid might be defective, requiring replacement. * The PC board could be defective, also requiring replacement.
  • D
    Dr. Jorge DominguezAug 2, 2025
    Why is my OK International Dispenser dispensing inconsistently?
    • N
      Noah LucasAug 2, 2025
      Inconsistent dispensing with your OK International Dispenser can stem from a few issues: * Air bubbles in the adhesives. Try reducing the vacuum setting. * The dispensing time might be too short. Increase the dispensing time. * The dispense needle may be clogged. Consider replacing the needle.
  • B
    Brendan LyonsAug 7, 2025
    What to do if my OK International DX-200 Dispenser system will not pressurize?
    • P
      Peter HancockAug 7, 2025
      If your OK International Dispenser system isn't pressurizing, it could be due to: * Insufficient air pressure. Increase the air supply pressure. * Air hoses not properly connected. Check the connections. * A defective regulator. Replace the regulator.
  • M
    Miss Elizabeth Edwards DVMAug 13, 2025
    Why will my OK International DX-200 Dispenser system not pull vacuum?
    • B
      Brett AlexanderAug 13, 2025
      If your OK International Dispenser system isn't pulling a vacuum, consider these potential causes: * The vacuum setting might be too low. Increase the vacuum setting. * A solenoid could be defective. Replace the solenoid valve. * The vacuum venturi might be defective. Replace the venturi. * The vacuum needle valve might be defective. Replace the needle valve.
  • L
    Luke AustinAug 20, 2025
    How to fix an OK International Dispenser when the LCD does not light?
    • C
      cassandramaysAug 20, 2025
      If the LCD on your OK International Dispenser doesn't light up, here are a couple of things to check: * Ensure the power cord is properly connected. * Make sure the power is turned on.

Summary

Safety

Intended Use

Defines the proper and intended applications for the equipment, warning against misuse for safety and property protection.

Safety Precautions

Outlines essential safety measures and warnings for operating the dispenser, including protective gear and specific model compatibility.

Symbol Definitions

Specifications

Features Overview

Connecting the Unit

Setup Instructions

Manual Dispense Cycle Setting

Step-by-step guide for configuring and performing manual dispensing cycles.

Automatic Dispense Cycle Setting

Instructions for setting up and performing automatic, timed dispensing cycles.

Operation Diagram and Cycle Counter

Troubleshooting

Maintenance

Spare Parts and Accessories

Limited Warranty

I;O Configuration and End of Cycle Switch

OK International DX-200 Specifications

General IconGeneral
BrandOK International
ModelDX-200
CategoryDispenser
LanguageEnglish