www.okinternational.com - 35 - P/N 7000-1370, Revision B
17. Adjust the gun sight adjustment screws located on the side of the camera until
the component gun sight overlays the PCBA gun sight.
18. Follow the directions on the screen.
19. To verify optical calibration, using the down action keys, lower the component
gun sight to the PCBA gun sight.
Adjustment
screws.
Note: The prism adjustment screws are adjusted as needed to overlay the
top and bottom gun sight images. Each of the four screws can be adjusted
as needed to achieve this.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com