940813000_09_012
(The following procedure must be done with the
main power supply isolated)
Retaining screw
entrance
Retaining screw
entrance
Alignment vial
Pre-etched entrance for the connection cable
(must be removed before thermostat’s installation)
Photo 1
Photo 2
Photo 3
Photo 4
Mounting screws
Installation procedure
Installation procedure
1 To install the device, use a flat blade screwdriver to
pry up the cover, with the same width as the plastic
opening (photo 2).
2 Unscrew the retaining screws and remove the
plastic cover containing the keys (photo 3).
3 Use the supplied support screws and plugs after
opening the required holes on the mounting surface
(photo 1). Install the base and align using the built-in
alignment vial. Tighten the retaining screws.
4 Press and remove the pre-etched cable entry
(photo 1). Perform the connections as shown in
the diagrams on page 8.
THE NEUTRAL IS NOT CONNECTED.
5 Reinstall with care the plastic with the keys and
fasten the mounting screws. Maximum tightening
torque 0,5 N*m.
6 To activate the device remove the battery
separator (photo 4).
7 Reinstall the plastic cover and press gently until it
snaps into position. The unit is ready to operate.