MAINTENANCE AND CARE INSTRUCTIONS
Olympia products are designed and engineered under strict quality standards. Regular and proper care of our
products will ensure years of trouble free service. To clean, simply wipe with a damp, soft cloth. Do not use
abrasive or harsh cleaners as they may result in nish damage.
TROUBLE SHOOTING
A. No Cold / Hot Water: 1. Shut off valve control. Reopen slowly when the
supply pressure is equalized.
2. Check water supply to hot & cold inlets. (Valve is designed
to shut-off in the event of water ow is
interrupted to either hot or cold inlets.)
3. Check valve inlet stops (B) to see that both are in the fully
open position. (Valve is designed to shut off if ow is
diminished to either side.)
B. Low Flow / No Temperature
Adjustment:
1. See above.
2. Close water supply and relieve the pressure.
3. Remove pressure balancing spool assembly (C). Clean
or replace. Flush the system. Reinstall and do not lube.
Restore the supply pressure.
INSTALLATION AND MAINTENANCE
INSTRUCTIONS FOR OLYMPIA SINGLE
HANDLE TUB AND SHOWER SETS
THIS PRODUCT MEETS THE FOLLOWING STANDARDS: ASME A112.18.1~ ANSI
A117.1 ~ UPC / IAPMO LISTED / ADA COMPLIANT
PRODUCT NUMBERS
#P-2300B Tub & Shower Valve Only With Inlet Stop
#P-2400B Tub & Shower Valve Only Without Inlet Stop
#P-2301B Tub & Shower Valve Only with Pex connections (Inlets & Shower Outlet) &
with Inlet stop
#P-2300CS Tub & Shower Set
#P-2300T* Tub & Shower Trim Only
#P-2301T* Tub Trim Only
#P-2302T* Shower Trim Only
#P-2303T* Valve Trim Only
#P-2340T* Tub & Shower Trim Only - Lever Handle
#P-2341T* Tub Trim Only - Lever Handle
#P-2342T* Shower Trim Only - Lever Handle
#P-2343T* Valve Trim Only
#P-2360T* Tub & Shower Trim Only - Lever Handle
#P-2361T* Tub Trim Only - Lever Handle
#P-2362T* Shower Trim Only - Lever Handle
ADA*
Olympia Faucets, Inc. © 2013
OLYMPIA FAUCETS, INC. LIMITED LIFETIME WARRANTY *
Olympia Faucets, Inc. warrants its products to the original consumer purchaser to be free from defects in material
and workmanship as long as the consumer purchaser owns it. Dated proof of purchase must accompany all war-
ranty claims. PVD nishes carry a lifetime warranty in residential service.
Olympia Faucets, Inc. will replace, free of charge, to the original consumer purchaser, any and all parts that
prove defective under normal installation, use, and service. Damage as a result of misuse, abuse, accident, or
improper installation, will consequentially void this warranty. Replacement parts can be obtained from your local
dealer or directly from Olympia Faucets. Olympia Faucets, Inc. recommends using a certied plumber for all
faucet installation and repair.
This warranty is limited to replacement of defective parts only. Incidental and consequential damages, labor
charges, repair, or replacement costs are expressly excluded. Some states do not allow the exclusion or limita-
tion of incidental or consequential damages, so the above limitation may not apply to you. This warranty gives
you specic legal rights, as you may have other rights of which vary from state to state.
Installation or maintenance and cleaning must be in compliance with instructions furnished with every Olympia
product. If you nd a problem with your product, please immediately contact your nearest Olympia Faucets, Inc.
dealer or sales representative.
* 2 year limited warranty on commercial and multi-family projects.
Question and Answer IconNeed help?

Do you have a question about the Olympia P-2300B and is the answer not in the manual?

Olympia P-2300B Specifications

General IconGeneral
BrandOlympia
ModelP-2300B
CategoryPlumbing Product
LanguageEnglish

Summary

Olympia Faucet Maintenance and Care

Troubleshooting Common Issues

Guidance for resolving issues like no water flow or temperature control problems with Olympia faucets.

Olympia Faucet Limited Lifetime Warranty

Olympia Single Handle Tub and Shower Set Installation

Product Model Numbers

List of available Olympia single handle tub and shower set model numbers for reference.

Olympia Single Handle Valve Installation Guide

Pre-Installation Important Information

Key precautions and advice to follow before beginning the installation process for Olympia valves.

Standard Valve Installation Procedure

Detailed steps for installing the valve body into the wall and connecting water supply lines.

Thin Wall Installation Techniques

Procedure for installing the valve when using thin wall construction or plaster/tile finishes.

Back-to-Back Installation Method

Instructions for installing the valve when the hot and cold inlets are reversed.

System Flushing Before Trim Installation

Procedure to flush water lines before installing the showerhead to remove debris.

Trim and Handle Installation

Steps for installing the decorative trim components, including the face plate, handle, and spout.

Olympia Pressure Balance Valve Temperature Adjustment

How to Adjust Temperature Limit Cap

Guide to setting the temperature limit cap for desired hot water access and safety.