4
Maintenance
Troubleshooting
SYMPTOMS POSSIBLE CAUSE
Compressorwillnotstart Checkifthepowercordhasbeenpluggedin.
Checkforblownfuse.
PoorPerformance Movetheunitfromdirectsunlight,andavoid
installingheatingdevicesneartheunit.
Installtheunitinawellventilatedplacewithminimum
of6”clearanceintheback.
Checkthecondenser,andcleanifheavydustis
collected.
Checktoseeifcontentsareblockingtheairduct.
Checktoseeifrefrigerantchargeislow.
Makesurethedooriscompletelyclosed.
NoInteriorLight Turnoffthelightswitchandturnitonagain.
Makesurethelightiscorrectlyinsertedintothe
sockets.
Checkthelight,andreplaceitifblown.
UnitNoisy Makesuretoinstalltheunitonlevelsurface.
Makesuretomaintaintheminimumclearanceof6”
fromthewall.
Checkfortheloosepartsormounting.
Makesurethetubingisfreefromanycontacttoavoid
tubingrattle.
• Whenloadingtheunit:
-Becarefulnottoblocktheairductlocatedatthebackandthefanontheceilingoftheunitwithcontents.
-Blockingtheairowmaycausedecreaseinperformance.
-Forthebestperformance,maintainatleast4inchesofclearancebetweenthecontentsandtheairduct.
• Settheshelvesthatcomewiththeunittotyourneeds.
• Temperaturecontroller:
-Thecontrollerislocatedattheright,frontcorneroftheceiling,oronthefrontbottompanel.
-Toadjusttemperaturepleaserefertothemanualoftemperaturecontroller.
• Donotleavetheunitdooropenforlongperiodoftime.Forthemostefcientoperation,closethedoor
immediatelyaftertheuse.