Cal. 1310
11
Technical guide
1973
CALIBRE
English
1310
29 Q SCS CALD CORR CORH CORS STS 8 jewels
Folder 4 - Diagnostic Disassembling Cleaning
Reassembling and lubrication of movement
IMPORTANT - To be observed strictly
The watch must in no case be demagnetized.
Do not touch the electronic module with the
fingers, nor unsolder the elements.
The motor module must IN NO CASE be
disassembled; the characteristics of the
magnetic circuit would be disturbed.
Do not clean the electronic module and motor
module in baths.
EQUIPMENT
Movement holder 1310.
Key for trimmer 1301.
Tool for adjusting motor eccentric.
Deltatest measuring apparatus.
Alitest checking apparatus.
Feed by substitute power cell 1310.
Microscope.