1973
Cal. 1310
10
3.42. Slightly unscrew the screw No. 2564 
(point 11, fig. 4.3.) for retaining click plate.
3.43. Engage click (6) on retaining wheel 
(12). The tip of the blade must be at the top 
of a tooth, as close as possible, without 
touching it (position a, fig. 5.3.). If necessary, 
move retaining click plate No. 1310.9026 
(13) by turning the eccentric of click bearing 
plate No. 1310.9029 (14).
3.44. Lock screw of retaining click plate. 
Check again the click position after having 
turned the stem according to fig. 5.3.
3.45. Start the watch by pushing hand setting 
stem. Engage click in retaining wheel by 
turning the click stud until the blade touches 
the tooth (c). Turn slightly further the click 
stud in order to tighten the blade (position b), 
and so that a space (d) appears between the 
end of the click and the tooth (e).
Important : The distance (d) between the 
end of the blade and the tooth (e) must be as 
small as possible. It is necessary to check 
during one minute at least the passage of the 
60 teeth of the retaining wheel. The click 
must never touch the tooth at point (e).
3.46. Fit second hand according
to op. 3.9. and 3.10.
3.47. Follow operation in the order 3.11 to 
3.16.
Fig. 4.3
Fig. 5.3