9-15
Meter Function Menus
9
9.2.7 CNT BY (Count By)
Count by is used to round off the meter values by 1’s, 2’s, 5’s, 10’s, 20’s,
50’s, or 100’s. This feature is normally set to “001” so that the display shows
all possible values for the least-significant digit.
If the combination of input-signal noise and selected resolution is high,
however, your meter can round off the display to the nearest 2, 5, 10, 20, 50
or even 100 digits. This can eliminate annoying display jitter without
introducing any filter time delays.
MENU MIN/MAX/MENU *
BUTTON BUTTON
MAIN MENU SUB MENU DESCRIPTION
“CNT BY”: COUNT BY ROUNDING OFF THE VALUE
“001”
“002” (the decimal point
“005” position is ignored)
“010”
“020”
“050”
“100”
* Press the ‘MIN’ button to show “001”, “002”, “005”, “010”, “020”, “050”, or
“100”.
Press the ‘MAX’ button to select one of the above.
Press the ‘MENU’ button to store the Count By number and the meter will
advance to “FIL.CNF”.
The underlined item is the factory preset value.