Summary

Recommended Location of Alarms

Ceiling Mounting Guidelines

Locate minimum 300mm from sidewall and inside corner.

Wall Mounting Guidelines

Use inside wall, top edge 300-500mm below ceiling, 300mm from corner.

Avoid These Locations

Kitchen and Garage Avoidance

Do not locate in kitchens (cooking smoke) or garages (vehicle exhaust).

HVAC and Ceiling Avoidance

Avoid forced air ducts, "A" frame ceilings, and peaks.

Environmental Condition Avoidance

Avoid areas with extreme temperatures or high humidity.

What To Do When Alarm Sounds

Immediate Actions During Alarm

Evacuate via escape plan, check doors for heat, stay low, call fire department from neighbor.

Understanding False Alarms

Causes and Response to False Alarms

Caused by cooking smoke or direct smoke blowing; check for fire first.

Installation and Mounting Information

Electrical Installation Warning

Must be installed by a qualified electrician per AS/NZ 3000.

Stand-alone vs. Inter-connected Operation

Alarm functions as stand-alone or can be interconnected up to 40 units.

Installation Steps

Sequence for power off, battery install, wiring connections, and mounting.

Wiring and Connection Details

Connect Live (L), Neutral (N), and Interconnect (I) wires securely.