EasyManua.ls Logo

Omega PX409-USB - Model PX409-USB Pressure Transducer

Omega PX409-USB
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Section 4 – Specifications cont’d.
Model PX409-USB Pressure Transducer
Accuracy: 0.08% Best Straight Line (linearity, hysteresis
and repeatability combined)
Temperature Compensation
Over Compensated Range: Span: 0.5%
Zero: 0.5%
Minimum Isolation Between: Case and Output Terminations:
100 MΩ @ 50 Vdc
Pressure Cycles: 1 million, minimum
Long Term Stability (1-Year): ±0.1% FS typical
A to D Conversion: 14-Bit
Shock: 50g, 11 mS half sine shock, (under test)
Vibration: ±20g (under test)
Bandwidth: DC to 100 Hz typical
CE Compliant: Meets industrial emissions and immunity
standard IEC61326 (pending)
Environmental Protection: IP65 or IP67 depending upon electrical
termination
Secondary Containment
Vacuum and Pressure: 10 inH
2
O to 5 psi: to 1000 psi
15 to 1000 psi: to 3000 psi
1500 to 5000 psi: to 15,000 psi
Secondary Containment
Absolute Pressure: 5 to 1000 psi: to 6000 psi
1500 to 5000 psi: to 15,000 psi
Wetted Parts: 316L SS
Weight: 200 g (7 oz)
Overpressure Gage Pressure: 10 inH
2
O: 10 times span
1 psi: 6 times span
2.5 psi to 3500 psi: 4 times span
5000 psi: 15,000 psi max
Overpressure Absolute Pressure: 5 psia: 6 times span
15 psia to 3500 psia: 4 times span
5000 psia: 15000 psi max
Operating Temperature Range: -40 to 85°C (-40 to 185°F)
Compensated Temperature: Ranges >5 psi: -29 to 85°C (-20 to 185°F)
Ranges ≤5 psi: -17 to 85°C (0 to 185°F)
Dimensions: PX409 USB Ranges up to 1000 PSIG, 4.4 L
PX409 USB Ranges above 1000 PSIG, 5.0 L
0.88 Dia.
Enclosure: 3/16 L Stainless Steel
Specifications
4
4-3