Do you have a question about the Omniwash ST series and is the answer not in the manual?
| Category | Dishwasher |
|---|---|
| Place settings | 13 |
| Number of programs | 6 |
| Delay start | Yes |
| Child lock | Yes |
| Dimensions (H x W x D) | 845 x 598 x 600 mm |
Machine installation must be by authorized personnel following instructions and regulations.
Do not use as ladder, avoid leaning on open door. Check for damage before installation.
Must be installed/repaired by authorized personnel. Incorrect work is hazardous.
Ensure correct earth connection. Manufacturer not liable for damages due to its absence.
Compare machine data with mains supply. Use qualified electrician for doubts.
Do not use extension cords; they do not guarantee sufficient safety.
Handle detergents/rinse aid with care. Use goggles/gloves. Do not inhale powder.
Do not open door during operation due to hot water splash. Beware heating elements.
Installation must be by qualified technical personnel according to instructions and regulations.
Connection must be by licensed, qualified technicians per current regulations.
Machine must be serviced with power, voltage, frequency, protection as specified on nameplate.
Verify wiring network has grounding and an overvoltage category III isolating switch.
Disconnect power from main switch by switching it 'OFF' before any work.
Connect power cable. Neutral wire must be correct. Cable is 'Y' type.
Connect earth wire to efficient earth. Electrical safety ensured by correct earth connection.
Equipment must be in equipotential system. Connection via screw marked 'EQUIPOTENTIAL'.
Machine is without tension and safe only when the mains switch is turned off.
Safety: use gloves/glasses with corrosive products. Access dispenser by removing front panel.
Respect safety for corrosive products. Clean systems when changing products. Use industrial products only.
Check electrical power, door closure, micro switch, water level switch, and solenoid valve.
Check tank water level switch, air pressure switch, water inlet tap, overflow, jets, and solenoid valve.
Check inlet tap, ON/OFF switch, 0-1 switch, overflow, jets, air gap, and solenoid valve.
Check water entry, tank/boiler heating elements, and safety thermostats.
Check drain pipe for blockage. Remove or replace pipe if necessary.
All LEDs blinking indicates alarm. Status indicated by LEDs. Normal operation restored by power cycle.
Alarms can indicate faulty probes, open thermostats, door open, solenoid issues, or slow filling.