Programmable Controllers SYSMAC CS1G/H 7
● Long-distance Expansion
Use this system configuration for an expansion of more 12 m. Expansion is possible by up to 50 m.
Using CS1 Connecting Cable and Long-distance Expansion Connecting Cable
I/O Control Unit (see note.)
CS1W-IC102
I/O Interface Unit
CS1W-II102
I/O Interface Unit
CS1W-II102
I/O Interface Unit
CS1W-II102
I/O Interface Unit
CS1W-II102
I/O Interface Unit
CS1W-II102
I/O Interface Unit
CS1W-II102
CS1 Expansion Rack
CS1 Expansion Rack
(Used for long-distance expansion.)
CS1 Expansion Rack
(Used for long-distance expansion.)
CS1 Expansion Rack
(Used for long-distance expansion.)
CS1 Expansion Rack
(Used for long-distance expansion.)
CS1 Expansion Rack
(Used for long-distance expansion.)
CS1 Expansion Rack
(Used for long-distance expansion.)
Connecting Cable for Long-distance Expansion CV500-CN@@2
Connecting Cable for Long-distance Expansion CV500-CN@@2
Connecting Cable for Long-distance Expansion
CV500-CN@@2
50 m
0.7 m
50 m
Connecting Cable for Long-distance Expansion
CV500-CN@@2
Connecting Cable for Long-distance Expansion
CV500-CN@@2
Connecting Cable for Long-distance Expansion
CV500-CN@@2
Terminator *
Terminator *
CPU Rack
CS1 I/O Connecting Cable CS1W-CN@@3
Power Supply Unit
C200HW-P@@@@(@)
Power Supply Unit
C200HW-P@@@@(@)
Power Supply Unit
C200HW-P@@@@(@)
Power Supply Unit
C200HW-P@@@@(@)
Power Supply Unit
C200HW-P@@@@(@)
Power Supply Unit
C200HW-P@@@@(@)
Power Supply Unit
C200HW-P@@@@(@
)
CS1 Expansion Backplane
CS1W
-BI@@@
CS1 Expansion Backplane
CS1W-BI@@@
CS1 Expansion Backplane
CS1W-BI@@@
CS1 Expansion Backplane
CS1W-BI@@@
CS1 Expansion Backplane
CS1W-BI@@@
CS1 Expansion Backplane
CS1W-BI@@@
CS1 Expansion Backplane
CS1W-BI@@@
(Used for long-distance expansion.)
The maximum number of Expansion Racks: 6 (In two levels)
Expansion Racks Configuration
• CS1 Expansion Rack
• CS1 Expansion Rack (Long-distance
expansion)
•Cable
Unit name Required number of units
I/O Control Unit
(CS1W-IC102)
1
Unit name Required number of units
CS1 Expansion
Backplane
(CS1W-BI@@@)
One required for each
Expansion Rack
Power Supply Unit
One required for each
Expansion Rack
I/O Interface Unit
(CS1W-II102)
One required for each
Expansion Rack
Maximum Number of
Configuration Units
Varies by backplane model
Cable name Required number of cables
CS1 I/O Connecting
Cable
(CS1W-CN@@3)
1
Connecting Cable for
Long-distance
Expansion
(CV500-CN@@2)
Number of CS1 Expansion
Racks minus 1
Note: If even one Long-distance Expansion Connecting Cable to be used, it is necessary for an
I/O Control Unit to be mounted to the CS1 Expansion Rack where the Cable is connected.
* Two Terminators (CV500-TER01) are provided with
the CS1W-IC102 I/O Control Unit.