EasyManua.ls Logo

Omron CJ2 Series User Manual

Omron CJ2 Series
86 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Machine Automation Controller NJ-series
EtherNet/IP
TM
Connection Guide
OMRON Corporation
CJ2-s
eries Controller
P568-E1-01
Question and Answer IconNeed help?

Do you have a question about the Omron CJ2 Series and is the answer not in the manual?

Omron CJ2 Series Specifications

General IconGeneral
CPU UnitsCJ2H, CJ2M
Data Memory Capacity32K words (CJ2M), 128K words (CJ2H)
EtherNet/IPYes (some models)
I/O CapacityUp to 2, 560 I/O points
Communication PortsEthernet, RS-232C
Expansion UnitsUp to 40 expansion units
Programming LanguagesLadder diagram, Structured text, Function block diagram
Instruction Execution Speed0.04 μs (basic instructions)
Serial Ports1 (RS-232C)
Expansion SlotsUp to 10 (CJ2H)
Operating Temperature0 to 55°C
Storage Temperature-25°C to 75°C
Power Supply Voltage100 to 240 VAC, 24 VDC

Summary

Related Manuals

Terms and Definitions

Precautions

Overview

Applicable Devices and Device Configuration

Applicable Devices

Lists the OMRON hardware components compatible with this guide.

Device Configuration

Details hardware and software components and versions for the setup.

EtherNet/IP Settings

EtherNet/IP Communications Parameters

Specifies IP addresses and subnet masks for EtherNet/IP communication.

Allocating the Tag Data Links

Explains mapping of device data to controller global variables.

EtherNet/IP Connection Procedure

Work Flow

Outlines the sequential steps for establishing EtherNet/IP connectivity.

Setting Up the PLC

Guides through configuring the PLC, including hardware and basic settings.

Setting Up the Controller

Details the process of setting up the controller using Sysmac Studio.

Setting Up the Network

Covers configuring the network using the Network Configurator tool.

Checking the EtherNet/IP Communications

Verifies the successful establishment of EtherNet/IP communication links.

Initialization Method

Initializing the Controller

Resets the controller's EtherNet/IP port and CPU unit to factory settings.

Initializing the PLC

Resets the PLC's EtherNet/IP Unit and CPU Unit to factory default settings.

Appendix 1 Detailed Settings of the Tag Data Links

Global Variable Table

Lists global variables used for tag data links and their parameters.

Relationship between Destination Device and Global Variables

Explains memory allocation between devices and global variables.

Associating the Tag Data Links

Describes the steps to link tags and create tag data link parameters.

Appendix 2 Setting the Tag Data Links Using the Software

Overview of Setting Tag Data Links

Introduces setting tag data links without configuration files.

Work Flow of "Procedure for Setting Parameters from the Beginning"

Provides a workflow for setting parameters without configuration files.

Setting Up the Controller without the Configuration Files

Details setting up the controller using software without pre-made files.

Setting Up the Network Using the Software

Explains network setup and configuration using software tools.

Related product manuals