Mounting of FH-L Series
Make sure to tighten all screws in mounting.
For good ventilation, provide a clearance of 50 [mm] or more above the Sensor Controller away
from other devices in the normal floor mounting. For the right and left sides, provide a clearance of
30 [mm] or more, and for the back side, 15 [mm] or more. These clearances are also required when
mounting multiple Sensor Controllers side by side. For the back mounting, the back-side clearance
of 15 [mm] is not required.
Do not install the product immediately above significant heat sources, such as heaters, transform-
ers, or large-capacity resistors.
Do not install the Sensor Controller in a cabinet with high-voltage equipment installed.
Mount the Sensor Controller at 200 [mm] or more from power cables apart.
l
Mounting the base of the Sensor Controller (Floor mounting)
Clearance: 50 mm
Clearance: 30 mm
Clearance: 15 mm
Clearance: 30 mm
52.9 15
59
Four, M4 depth 6.5
10.5
80
22 100
Recommended tightening torque: 0.54 to 0.6 N•m
The tolerance: ±0.2 mm
5 Setup and Wiring
5-15
FH Series Vision System Hardware Setup Manual (Z366-E1)
5-3 Sensor Controller Installation
5
5-3-3 FH-L Series