EasyManua.ls Logo

Omron RS4 HEM-6181-E - Page 12

Omron RS4 HEM-6181-E
12 pages
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Your monitor automatically stores up to 60 readings.
4.1 Viewing the Readings Stored in Memory
1. Press the button.
The Memory number appears for one second before the pulse
rate is displayed. The most recent reading set is numbered “1”.
Note
If the positioning indicator is enabled, the positioning
indicator is displayed with the readings.
If the reading is high (refer to section 1.3),
the “ ” symbol appears.
If there are no readings stored in the
memory, the screen to the right is displayed.
If the memory is full, the monitor will delete
the oldest readings.
2. Press the button repeatedly to scroll through the
previous readings stored in the memory.
4.2 Viewing the Average Reading
Your monitor can calculate an average reading based on the latest 2
or 3 readings taken within 10 minutes span.
1. When your monitor is off, press and hold the
button for more than 2 seconds.
Note
If there are only 2 readings in the memory
for that period, the average will be based on
these 2 readings.
If the average reading is high (refer to
section 1.3), the “ ” symbol appears.
4.3 Viewing Morning Weekly Averages
Your monitor calculates and displays weekly averages for the
measurements taken in the morning for 4 weeks.
1. Press the button once.
The morning weekly average for the current
week “THIS WEEK” appears on the display.
If the morning weekly average is high (refer to
section 1.3), the “ ” symbol appears.
2. Press the button repeatedly to display the average
for the previous weeks.
Your monitor displays “-1 WEEK” for the previous week's
average, to “-3 WEEK” for the oldest set of averages.
3. Press the [START/STOP] button to turn off your monitor.
Morning Weekly Average Calculation
This is the average for the measurements taken during the morning
(4:00 - 9:59) between Sunday and Saturday. Only the first 3
measurements taken in the morning between 4:00 - 9:59 will be
used to calculate the morning average for each day.
4. Using Memory Function
Alternating
date/time
display
9:59
4:00
Measurements of the morning
The first 3 measurements
4
3
2
1
Sunday Monday Tuesday Wednesday Thursday Friday Saturday
5.1 Disabling/Enabling Positioning Indicator
The positioning indicator is enabled as default.
1. When your monitor is off, press and hold the button
for more than 10 seconds.
Note
Your monitor will automatically turn off after 3 seconds from
the completion.
To enable the positioning indicator, follow the same steps as
above.
5.2 Deleting All Readings Stored in Memory
1. Press the button, then the “ ” symbol appears.
2. While holding the
button down, press
and hold the [START/
STOP] button for more
than 2 seconds.
Note
All readings will be deleted. You cannot partially delete the
readings stored in the memory.
In case of any of the below problems occur during measurement,
first check that no other electrical device is within 30cm. If the
problem persists, please refer to the table below.
5. Other Settings
6. Error Messages and Troubleshooting
Display/
Problem
Possible Cause Solution
appears or the
wrist cuff does
not inflate.
The wrist cuff is not
applied correctly.
Apply the wrist cuff
correctly, then take
another measurement.
Refer to section 2.4.
Air is leaking from the
wrist cuff.
Contact your OMRON
retail outlet or
distributor.
appears
The wrist cuff is
overinflated exceeding
300 mmHg.
Do not touch the wrist
cuff while taking a
measurement.
appears
You move or talk during
a measurement.
Vibrations disrupt a
measurement.
Remain still and do not
talk during a
measurement.
appears
The pulse rate is not
detected correctly.
Apply the wrist cuff
correctly, then take
another measurement.
Refer to section 2.4.
Remain still and sit
correctly during a
measurement.
If the “ ” symbol
continues to appear, we
recommend you to
consult with your
physician.
/
appears
appears
appears
Your wrist is moved up
and down during a
measurement.
Do not move your wrist,
then take another
measurement.
Refer to chapter 3.
appears
The monitor is
malfunctioned.
Press the [START/
STOP] button again. If
“Er” still appears,
contact your OMRON
retail outlet or
distributor.
The heart
symbol in the
positioning
indicator does
not appear and
a locator bar
does not
appear.
The positioning indicator
is disabled.
Enable the positioning
indicator. Refer to
section 5.1.
flashes
Batteries are low.
Replacing all batteries
with 2 new alkaline
batteries is
recommended. Refer to
section 2.1.
heart symbol
7.1 Maintenance
To protect your monitor from damage, please follow the directions
below:
Changes or modifications not approved by the manufacturer will
void the user warranty.
Caution
DO NOT disassemble or attempt to repair this monitor or other
components. This may cause an inaccurate reading.
7.2 Storage
Keep your monitor in the storage case when not in use.
Store your monitor in a clean, safe location.
Do not store your monitor:
If your monitor is wet.
In locations exposed to extreme temperatures, humidity, direct
sunlight, dust or corrosive vapors such as bleach.
In locations exposed to vibrations or shocks.
7.3 Cleaning
Do not use any abrasive or volatile cleaners.
Use a soft dry cloth or a soft cloth moistened with neutral soap to
clean your monitor and wrist cuff, and then wipe them with a dry
cloth.
Do not wash or immerse your monitor and wrist cuff in water.
Do not use gasoline, thinners or similar solvents to clean your
monitor and wrist cuff.
7.4 Calibration and Service
The accuracy of this blood pressure monitor has been carefully
tested and is designed for a long service life.
It is generally recommended to have the unit inspected every two
years to ensure correct functioning and accuracy. Please consult
your authorised OMRON dealer or the OMRON Customer Service
at the address given on the packaging or attached literature.
appears or the
monitor is
turned off
unexpectedly
during a
measurement
Batteries are depleted.
Immediately replace all
batteries with 2 new
alkaline batteries. Refer
to section 2.1.
No power.
Nothing
appears on the
display of the
monitor.
Batteries are completely
depleted.
Battery polarities are not
properly aligned.
Check the battery
installation for proper
placement. Refer to
section 2.1.
Readings
appear too high
or too low.
Blood pressure varies constantly. Many factors
including stress, time of day, and/or how you
apply the wrist cuff, may affect your blood
pressure. Review sections 2.3 - 2.5 and chapter
3.
Any other
problems occur.
Press the [START/STOP] button to turn the
monitor off, then press it again to take a
measurement. If the problem continues, remove
all batteries and wait for 30 seconds. Then re-
install batteries.
If the problem still persists, contact your OMRON
retail outlet or distributor.
7. Maintenance
Display/
Problem
Possible Cause Solution
Note
These specifications are subject to change without notice.
In the clinical validation study, K5 was used on 85 subjects for
determination of diastolic blood pressure.
This monitor is clinically investigated according to the
requirements of ISO 81060-2:2013.
IP classification is degrees of protection provided by enclosures in
accordance with IEC 60529. This monitor is protected against
solid foreign objects of 12.5 mm diameter and greater such as a
finger, and against oblique falling water drops which may cause
issues during a normal operation.
This device has not been validated for use on pregnant patients.
Thank you for buying an OMRON product. This product is
constructed of high quality materials and great care has been taken
in its manufacturing. It is designed to give you every satisfaction,
provided that it is properly operated and maintained as described in
the instruction manual.
This product is warranted by OMRON for a period of 3 years after
the date of purchase. The proper construction, workmanship and
materials of this product is warranted by OMRON. During this period
of warranty OMRON will, without charge for labour or parts, repair or
replace the defect product or any defective parts.
The warranty does not cover any of the following:
A. Transport costs and risks of transport.
B. Costs for repairs and / or defects resulting from repairs done by
unauthorised persons.
C. Periodic check-ups and maintenance.
D. Failure or wear of optional parts or other attachments other than
the main device itself, unless explicitly warranted above.
E. Costs arising due to non-acceptance of a claim (those will be
charged for).
F. Damages of any kind including personal caused accidentally or
from misuse.
G. Calibration service is not included within the warranty.
Should warranty service be required please apply to the dealer
whom the product was purchased from or an authorised OMRON
distributor. For the address refer to the product packaging / literature
or to your specialised retailer. If you have difficulties in finding
OMRON customer services, contact us for information.
www.omron-healthcare.com
Repair or replacement under the warranty does not give rise to any
extension or renewal of the warranty period.
The warranty will be granted only if the complete product is returned
together with the original invoice / cash ticket issued to the
consumer by the retailer.
8. Specifications
Product category Electronic Sphygmomanometers
Product description Automatic Wrist Blood Pressure Monitor
Model (Code) RS4 (HEM-6181-E)
Display LCD digital display
Cuff pressure range 0 to 299 mmHg
Blood pressure
measurement range
SYS: 60 to 260 mmHg
DIA: 40 to 215 mmHg
Pulse measurement
range
40 to 180 beats / min.
Accuracy
Pressure: ±3 mmHg
Pulse: ±5% of display reading
Inflation Automatic by electric pump
Deflation Automatic rapid deflation
Measurement method Oscillometric method
Operation mode Continuous operation
IP classification IP 22
Rating DC3 V 3.0 W
Power source 2 “AAA” alkaline batteries 1.5V
Battery life
Approximately 300 measurements (using
new alkaline batteries)
Durable period (Service
life)
5 years
Operating conditions
+10°C to +40°C / 15 to 90% RH (non-
condensing) / 800 to 1060 hPa
Storage / Transport
conditions
-20°C to +60°C / 10 to 90% RH (non-
condensing)
Weight
Approximately 86 g not including
batteries
Dimensions
Approximately 93 mm (w) × 62 mm (h) ×
20 mm (l)
(not including the wrist cuff)
Measurable wrist
circumference
13.5 to 21.5 cm
Memory Stores up to 60 readings
Contents
Monitor, storage case, 2 “AAA” alkaline
batteries, instruction manual
Protection against
electric shock
Internally powered ME equipment
Applied part Type BF (wrist cuff)
Maximum temperature
of the applied part
Lower than +48°C
9. Limited Warranty
This device fulfils the provisions of EC directive 93/42/EEC
(Medical Device Directive).
This blood pressure monitor is designed according to the
European Standard EN1060, Non-invasive sphygmomanometers
Part 1: General Requirements and Part 3: Supplementary
requirements for electromechanical blood pressure measuring
systems.
This OMRON product is produced under the strict quality system
of OMRON HEALTHCARE Co., Ltd., Japan. The Core component
for OMRON blood pressure monitors, which is the Pressure
Sensor, is produced in Japan.
Important information regarding Electro Magnetic Compatibility
(EMC)
Correct Disposal of This Product (Waste Electrical & Electronic
Equipment)
10. Guidance and Manufacturer’s Declaration
Symbols description
Applied part - Type BF
Degree of protection against electric
shock (leakage current)
Ingress protection degree provided by
IEC 60529
CE Marking
Serial number
Temperature limitation
Humidity limitation
Atmospheric pressure limitation
Need for the user to consult this
instruction manual.
Indicates the correct positioning for the
monitor on the wrist
Measurable wrist circumference
Battery
Direct current
HEM-6181-E manufactured by OMRON HEALTHCARE Co., Ltd. conforms to
EN60601-1-2:2015 Electro Magnetic Compatibility (EMC) standard.
Further documentation in accordance with this EMC standard is available at
www.omron-healthcare.com. Refer to the EMC information for HEM-6181-E on the
website.
This marking shown on the product or its literature, indicates that it
should not be disposed of, with other household wastes at the end
of its working life.
To prevent possible harm to the environment or human health from
uncontrolled waste disposal, please separate this product from
other types of wastes and recycle it responsibly to promote the
sustainable reuse of material resources.
Household users should contact either the retailer where they purchased this
product, or their local government office, for details of where and how they can
return this item for environmentally safe recycling.
Business users should contact their supplier and check the terms and conditions of
the purchase contract. This product should not be mixed with other commercial
waste for disposal.
IP XX
Made in Vietnam
Manufacturer
53, Kunotsubo, Terado-cho, Muko, KYOTO,
617-0002 JAPAN
EU-representative OMRON HEALTHCARE EUROPE B.V.
OMRON HEALTHCARE Co., Ltd.
OMRON HEALTHCARE UK LTD.
Scorpius 33, 2132 LR Hoofddorp,
THE NETHERLANDS
www.omron-healthcare.com
Production
facility
Subsidiaries
Opal Drive, Fox Milne, Milton Keynes, MK15
0DG, UK
www.omron-healthcare.com
OMRON MEDIZINTECHNIK
HANDELSGESELLSCHAFT mbH
Konrad-Zuse-Ring 28, 68163 Mannheim,
GERMANY
www.omron-healthcare.com
OMRON SANTÉ FRANCE SAS
14, rue de Lisbonne, 93561 Rosny-sous-Bois
Cedex, FRANCE
www.omron-healthcare.com
OMRON HEALTHCARE MANUFACTURING
VIETNAM CO., LTD.
No.28 VSIP II, Street 2, Vietnam-Singapore
Industrial Park II, Binh Duong
Industry-Services-Urban Complex,
Hoa Phu Ward, Thu Dau Mot City,
Binh Duong Province, Vietnam

Related product manuals