EasyManua.ls Logo

Onlyfire 7026 - Final Assembly and Leak Testing

Default Icon
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9
Portable Tabletop Fire Pit
F-FPR7026-BK1
Step 7: Pour the fire glass into the middle of the fire pit body evenly
WARNING: To ensure proper function, the guard on the burner should be free of fire glass at all
times.
WARNING: Make sure that the holes on the inside wall of the fire pit body stay unclogged of
fire glass.
LEAK TEST:
Before performing a leak test, be sure that no sparks can occur and you are in a spacious outdoor
area. Connect the propane gas tank to the regulator and turn the valve on the unit to the off
position. Brush a soap and water mixture on all connections. Turn the gas supply on; if bubbles
occur on any connection there may be a leak. If you smell gas or a leak is discovered turn the gas
valve off, disconnect propane gas tank and do not use the appliance until the leak is repaired.
Do not use the heating unit without inspecting the gas hose. If there are signs of wear or abrasion
you must replace the hose (if applicable). Pumice stones/lava rocks/fire glass could pop up and
strike somebodys face during the process of lighting this unit; stand away from the unit for the
first 20 minutes after igniting. Flame height should be a yellow/blue color between 2 - 10 inches
in height.