GB
OPERATING MANUAL
WA
IMPORTANT NOTICE
Please read the Operating Manual
carefully before attempting to install
or service the air exhaust fan!
Manufacturer shall not be liable for
any damage resulting from incorrect
operation, non-intended use or
unauthorized repair or modifications of
the product.
The Operating Manual and the
installation instructions contained
in it are an essential part of the
product equipment. The Operating
Manual specifies important technical
information and instructions for the
operating safety of the air exhaust fan.
Carefully read the installation
instructions in the Operating Manual.
Keep the Operating Manual available
for future reference.
Warnings
Follow all safety regulations and the
safety symbols shown in the Operating
Manual to avoid injury and hazards.
Safety precautions:
• This product can be used by children
at least 8 years old, by people with
impaired physical and/or mental
abilities, and by people without any
experience in or understanding of the
operation of the product, if supervised
or instructed by a competent adult in
the safe use of the product so that they
understand the relevant operating risks.
This product is not a toy and children
should not play with it. Children should
not be allowed to clean or maintain the
product without supervision of an adult.
• The fan is intended for permanent
installation and connection with the
building electrical system. The building
electrical system connected to the fan
must be capable of breaking live voltage
contact on all switching poles to fully
isolate the fan from power. Category III
overvoltage conditions, in accordance
to applicable electrical engineering
regulations.
• The fan is designed for installation at
a substantial height, i.e. 2.3 m abov
e the
door. The fan shall only be installed in
a position and an orientation specifieed
in the Operating Manual, given the
necessary entry of the power cable into
the fan housing.
• Before servicing the fan, isolate it
from the mains voltage with the circuit
breaker. Secure the circuit breaker
against inadvertent operation flow.
• The air exhaust fan installation design
must prevent reverse flow of flue
gas into the room from open flue gas
exhaust ducts and appliances operated
with open flames.
• Never attempt to modify or alter the
fan without authorization.
• Before installing the fan, verify the
load bearing capacity of the installation
substructure. Improper installation
fastening may result in damage or
failure of the fan and
hazards to the people nearby. The
fan can be hazardous when operated
against its intended use or installed by
unqualified personnel.
Application and operating conditions
• The air exhaust fan is intended for
handling air of normal quality or with
a low dust content (with a particle size
< 10 µm) and of low aggressiveness
and humidity. The air exhaust fan is
intended for operation in temperate
climate conditions and within the
performance limits specified in the
product catalogue.