16
Chapter
Chapter
Chapter
Chapter 7
7
7
7 Basic
Basic
Basic
Basic Operation
Operation
Operation
Operation
7.1
7.1
7.1
7.1 Power
Power
Power
Power Connection
Connection
Connection
Connection
Battery power and DC power were supplied to provide
convenience , and the DC power was connected to the AC
power through an adapter, please make sure the voltage of AC
power is 110V- 240V! When the Fusion was connecting the DC
power, the battery was charged.
7.2
7.2
7.2
7.2 Splicing
Splicing
Splicing
Splicing Parameter
Parameter
Parameter
Parameter Setting
Setting
Setting
Setting
Turn on the power and then the instrument begin self-checking.
If everything was ready, splice mode would be entered, the
display on the screen is as figure 2-2.
7.2.1
7.2.1
7.2.1
7.2.1 Main
Main
Main
Main Menu
Menu
Menu
Menu
Enter
Enter
Enter
Enter The
The
The
The Main
Main
Main
Main Menu
Menu
Menu
Menu
In the splice mode, press the key and the instrument will
enter the menu mode. The screen displays the main menu as
figure 7-1.
Functions
Functions
Functions
Functions in
in
in
in the
the
the
the Main
Main
Main
Main Menu
Menu
Menu
Menu
The s ymbol is a highlight rectangle which can be moved up or
down by or key. Functions in the main menu are as
follows:
“
“
“
“ Fiber
Fiber
Fiber
Fiber Type
Type
Type
Type ”
”
”
” :
:
:
:
To select fiber type.
“
“
“
“ Para.
Para.
Para.
Para. Group
Group
Group
Group ”
”
”
” :
:
:
:
Select the discharge condition group , adjust
the discharge parameters .
“
“
“
“ H
H
H
H eat
eat
eat
eat T
T
T
T ime
ime
ime
ime ”
”
”
”
: Adjust heating time .