ENCLOSURE RECOMMENDATION
HCCA122 & HCCA124 VENTED 2000+ WATTS INPUT
c
b
—Box Parts—
Box Shape – Square Prism
1 Top, 1 Bottom
depth (c) = 18.36 in. (466 mm)
width (b) = 22 in. (559 mm)
thickness = 1 in. (25.4 mm)
1 Front, 1 Back
height (a) = 14 in. (356 mm)
width (d) = 20 in. (406 mm)
thickness = 1 in. (25.4 mm)
2 Sides
height (a) = 14 in. (356 mm)
depth (c) = 18.36 in. (466 mm)
thickness = 1 in. (25.4 mm)
Driver Mounting
Mounting: Front
Top &
Bottom
a
d
Front
& Back
c
Sides
A
B
C
External Dimensions
A = 16 in. (406 mm)
B = 22 in. (559 mm)
C = 18.36 in. (466 mm)
Internal Dimensions
A = 14 in. (356 mm)
B = 20 in. (406 mm)
C = 16.36 in. (416 mm)
Wall Thickness
Front = 1 in. (25.4 mm)
Sides = 1 in. (25.4 mm)
h
e
h
g
Vent Parts
1 Top, 1 Bottom
width (e) = 3.5 in. (89 mm)
length (h) = 30.33 in. (770 mm)
thickness = 0.75 in. (19 mm)
2 Sides
height (g) = 14 in. (356 mm)
length (h) = 30.33 in. (770 mm)
thickness = 0.75 in. (19 mm)
Box Properties
Description
Type: Vented Box
Shape: Prism, Square
Box Parameters
Vb = 1.5 cu.ft
V(total) = 2.65 cu.ft
Fb = 40 Hz
QL = 5.256
F3 = 32.98 Hz
Fill = none
Vents
No. of Vents = 1
Vent shape = rectangle
Vent ends = one flush
Hv = 14 in. (356 mm)
Wv = 2 in. (51 mm)
Lv = 30.33 in. (770 mm)