90
5.8 -
1 Check, all four main valves is open.
2 Check oil level in container, chain lubricaon system and level of grease in
reservoir for the automac grease lubricaon system.
3 Check the pressure relief valve for any visual grease. If grease appear on the
valve, it indicate a clogging in the system. Repair the fault before start.
4 Check the tension on chains and conveyor belts.
5 Look for any leakages in the hydraulic system.
6 Check the levelling of the compactor.
7 Check the oil temperature according to start - up procedure. Chapter 4.4.5
1 Observe all machine movements and funcons.
2 Check the chamber belts tracking. Adjust if necessary.
3 Check, the automac greaser pump is running. Frequently
4 Keep an eye on chains if there’s oil present. Dry chains? Check the system.
5 Check the condion of chamber rollers for any build up materials. Be aen-
ve to the rollers and belts.
6 Avoid overlling of elevator and subsequent too much build up of material
in space under the elevator.