8 170809
Normal display, (figure 1):
The current temperature is shown in the display. Any deviation from +2-+8 °C will trigger an alarm and
the red alarm lamp lights.
Temperature log, (figure 2):
This displays the temperature as a diagram (figure 3) for a 24 hour period, logged every 15 minutes.
Use the up/down arrow to change the 24 hour period. The left/right arrow changes the time by 15
minutes. The temperature is shown at the bottom right.
Alarm history and min/max (figure 4)
Alarm History: The latest alarms are logged in the alarm history (figure 5), in date order. The latest
alarm is displayed at the top. The min/max menu shows when the temperature has been outside the
2-8 degree range, 365 days back in time.
Search min/max (figure 6): Use "search min/max" to search for the highest and lowest temperatures
over the past 24 hours.