EasyManua.ls Logo

OTARI MX-5050 B-II - User Manual

OTARI MX-5050 B-II
2 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Alignment Procedure for Otari MX-5050 B-II
Set SRL switch to SRL position.
PLAYBACK
1. Set the Reference Flux, and EQ to suit the test tape
2. AZIMUTH
a. Adjust for 0º ø on oscilloscope (A4 screw)
3. REPRO LEVEL
a. Play 0VU @ 1kHz and adjust VR106/VR206 for 0VU
4. REPRO EQ
a. Play ƒ sweep and adjust VR102/VR202 for a flat response (15 ips)
b. Play ƒ sweep and adjust VR103/VR203 for a flat response (71/2 ips)
RECORD
1. AZIMUTH
a. Adjust for 0º ø on oscilloscope (A3 screw)
2. RECORD METER LEVEL
a. Set the input level controls to maximum
b. Record 1kHz from a -15dBm source
c. Adjust the Record Level trimpot for 0VU
d. Switch to monitor Source
e. Adjust VR108/208 for 0VU
3. RECORD LEVEL
a. Set the Record flux level switch to M (250nW)
b. Monitor ‘Sourceand set the level to 0VU
c. Monitor ‘Tape’ and start recording
d. Adjust the Record Level trimpot for 0VU
Question and Answer IconNeed help?

Do you have a question about the OTARI MX-5050 B-II and is the answer not in the manual?

OTARI MX-5050 B-II Specifications

General IconGeneral
BrandOTARI
ModelMX-5050 B-II
CategoryRecording Equipment
LanguageEnglish

Related product manuals