Functio
n No.
Name
SVT Display
Setting Range
Defau
lt
Rang
e
Attribute
limit
20
Close
speed
Close speed
mm/s
0~508mm/s
508
21
Reverse
open
deceleration
Ropen dece
mm/s2
500~9999mm/s/
s
9000
22
Reverse
open jerk
deceleration
Ropen Jerk
mm/s3
500~9999mm/s/
s/s
1200
23
Demo open
arrive hold
time
Demo open hold
s
0~999.9s
003.0
24
Demo close
arrive hold
time
Demo clos hold
s
0~999.9s
003.0
25
Manual
acceleration
Man accel
mm/s2
10~2048mm/s2
0300
26
Manual
deceleration
Man decel
mm/s2
10~2048mm/s2
0500
27
Manual
speed
Man speed
mm/s
0~999mm/s
0050
28
Master or
slave status
setting
Master or Slave
0: master,
reopen is
allowed
1: slave, reopen
is not allowed
0
29
DOL Power
Reset Delay
DOL_PRD
0~9999
2000
M3316(VF parameters)
0
Current
sampling
AD offset
mode
AD OFFSET
mode
0:Auto offset
1:Manual offset
2:No offset
0
1
Torque
boost
TORQUE_BOO
ST
0~50.0%
20.0
%
2
Current
sampling
AD offset
Manual
offset for W
phase
AD OFFSET W
0~1000
3
Current
sampling
AD offset
Manual
offset for V
phase
AD OFFSET V
0~1000
4
Baffle
detection
switch
frequency
Baffle freq sw
0~99.99HZ
00.50
5
Force open
Force open
0~4