M43-31281 BK1.5 REV A1
7
wide range of applications. Configurations include a standard AC to DC wall transformer, a cigarette
lighter adapter or twisted wire for connection to a hard 12 VDC source such as a car, boat or RV
battery circuit. Most supply voltages fluctuate, so it is necessary to monitor your voltage and assure it is
within acceptable variance values listed below.
Voltage = (Specified) 11.7 VDC to 13.9 VDC
Frequency = Not applicable
Power Consumption = 600 ma @12vdc (7.2 watts) nominal
6.0 Maintenance
The Poseidon generators are delivered factory tested, calibrated, and adjusted for maximum efficiency and
long life. Simple maintenance and appropriate operating conditions are the only requirements to keep the
unit functioning within manufacturer's specifications.
Performing any other modifications or adjustments to internal components will cause the unit to function
outside of manufacturer's specifications, and will cause damage to the unit not covered under terms of
warranty.
6.1 Ozone Generator Maintenance
Frequency of Maintenance
Every 4800 hours (6 months)
To maintain the Ozone Generator:
1. Disconnect unit from power source.
2. Remove top cover.
3. Inspect the inside of the generator for dust and moisture.
4. Thoroughly clean and dry the inside of the generator.
5. Replace top cover.
6. Replace any ozone resistant check valves on the air in or ozone gas outlet lines.