- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ▲ INSTRUCTION MANUAL
MEGA-T300 Abrasive Cutter
3601 E. 34th St. Tucson, AZ 85713 USA Tel. +1 520-882-6598 Fax +1 520-882-6599 email: pace@metallographic.com Web: http://www.metallographic.com
Please read this instruction manual carefully and follow all installation, operating and safety guidelines.
3.4 Safety Tests
!
Examine and verify that the MEGA-T300 safety devices
and operating performance are in good working
condition prior to use. The following safety checks are
considered important:
Emergency stop switch
Magnetic Safety switch
11
Test: Activate main switch and close hood;
depress emergency stop switch.
Proper
Response:
Machine powers down.
Malfunction: Machine does not lose power.
Corrective
measure:
If system does not power down,
disconnect power supply cord and call
service technician.
Magnetic safety lock out switch
Test: Activate main switch and close hood;
turn cut-off wheel ON then OFF;
Try to open the hood.
Proper
Response:
Hood does not open for approximately 5
seconds.
Malfunction: Hood opens immediately.
Corrective
measure:
If cut-off wheel does not power down,
disconnect power supply cord and call
service technician.
Emergency stop switch