A
Angela ReeseAug 16, 2025
How to fix insufficient water to scrub head on Pacific Floorcare RS28?
- EErika HarrisAug 16, 2025
If your Pacific Floorcare Scrubber isn't providing enough water to the scrub head, several factors could be at play. First, ensure the solution flow isn't set too low by adjusting the solution control. Check if the solution tank is empty and add water or solution as needed. Inspect the in-line solution filter for clogs and clean it if necessary. Also, examine the solution tube for any clogs, kinks, or damage. Make sure the solution shut-off valve is open. Finally, verify the operation of the pump, pump wires, operator control board, and solution solenoid valve, replacing any damaged components. If your machine has a chemical injection system, ensure the chemical injection pump is running.