P2 User Manual Version 1.0
9
Non-Admin Level User System Access Restriction: If enabled, only accounts created with
administrator access will be able to access the P2 and make changes.
Enable Web Access: Enables you to access the P2 through the web interface.
Enable Telnet: Enables you to access the P2 using Telnet.
Enable Telnet Anonymous User: Enables you to allow anonymous logins using Telnet with no need
for a username or a password.
Enable Command Control via Email: Enables you to send emails to the P2 to manage it from a remote
location.
Enable SNMP Agent: Enables Simple Network Management Protocol that allows you to receive
information about the system for specific elements or objects on the network.
SNMP Community String: If SNMP is enabled, you can set this option to:
o Public: Provides Read Only Access to network elements.
o Private: Provides Read-Write Access to network elements.
o Trap: A command or message used by the Agent to inform the manger of a certain event.
SNMP Trap Receiver IP Address: If SNMP is enabled, you need to specify an IP address for the
destination where you want to receive the trap notifications.
Current Alarm Threshold (Pre-defined threshold): If current goes above the threshold for circuit A, the
P2 will send an Alert and sound an alarm.
Temp Alarm Threshold (Pre-defined threshold): If the temperature goes above the threshold, the P2
will send an Alert and sound an alarm.
Enable Alarm Beep: If a value goes beyond the desired threshold, an Alarm will sound. You can
enable/disable the beep.