When you are in the field:
Find a flat area! Always place kit on a
firm surface where it is easy to work
Work in the shade where possible!
Use the work surface in the kits - sterilise
it before commencing and repeat as
necessary to avoid cross-contamination
After sterilisation of the MFU, rinse the
sample cup 3 times with the sample
to remove any traces of methanol
Remember: The MFU apparatus needs
to be sterilised BEFORE you take
each new sample - not just prior to
the first sample
Remember: After preparing samples
for incubation, label each petri dish
with the relevant information - sample
no./time/source name etc. using
the pen provided
Remember: If collecting the sample in
a bottle, store below 4ºC and analyse
within 4-6 hours
Remember: Switch the incubator on
30 minutes before use to allow time for
incubation temperature to be reached.
The incubator will show ‘warming up’
during this initial period
Remember: At least one hour
and no more than four hours for
resuscitation periods
Ensure you have considered the following
additional items that may be required in
addition to the Potatest
®
+ contents:
Sterilised sampling bottles/
Wagsac sampling bags
Result form/log book
Methanol
Non-electric autoclave/pressure cooker
Cigarette lighter
Paper towel
Liquid detergent
De-ionised water
Waste disposal bags
Cool box/icepacks
Before leaving for the field, ensure
the following has been carried out:
The equipment is sterilised
wherever possible
Sufficient petri dishes, absorbent
pads, membrane filters, culture
media and reagents are available
Prepare MLSB media in Media
Measuring Device (MMD) - enough
for one day’s testing. If using
previously prepared media ensure
the media is still bright pink and
is not cloudy
If time is available, prepare the petri
dishes with pads before travelling to
the field. This also allows absorbent
pads to avoid contamination in the field
If dishes are prepared before
departure, an additional one or
two are recommended for potential
mishaps in the field
Sterilise the Membrane Filtration Unit
(MFU) so it is ready for immediate use
Note: Field testing requires careful planning
33
9
Appendix 1 - Field Testing Check List - Hints

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the palintest Wagtech Potatest + and is the answer not in the manual?

palintest Wagtech Potatest + Specifications

General IconGeneral
Brandpalintest
ModelWagtech Potatest +
CategoryTest Equipment
LanguageEnglish