Measurement Principle | Ultrasonic |
---|---|
Accuracy | ±1% of reading |
Repeatability | ±0.2% of reading |
Temperature Range | -40 to 140°F (-40 to 60°C) |
Power Supply | 100 to 240 VAC, 50/60 Hz |
Output Signal | 4-20 mA |
Communication | HART, Modbus |
Enclosure | IP66, NEMA 4X |
Fluid Types | Liquids, gases |
Inputs | Temperature |
Pressure Rating | Up to 100 bar (1450 psi) |
Explains different types of information notes, warnings, and cautions.
Highlights general safety considerations and responsibilities.
Discusses safe operation of auxiliary equipment.
Emphasizes adherence to local safety regulations.
Warns about potential hazards in the working area.
Requires manufacturer-approved training and appropriate safety gear.
Details WEEE directive compliance and recycling encouragement.
Outlines key topics for safe and reliable system installation.
Guidelines for selecting sites for enclosure, flowcell, and transducers.
Describes flowcell installation methods using spoolpieces or existing pipe.
Information on mounting the XGF868i enclosure and its features.
Introduces the process of making electrical connections to the transmitter.
Instructions for connecting AC or DC line power to the unit.
Steps for connecting transducers and preamplifiers.
Procedures for wiring standard analog outputs.
Instructions for connecting the RS232 serial interface.
General steps for wiring option cards in Slot 1.
Illustrates dimensions and mounting details of the electronics enclosure.
Illustrates internal wiring connections for various interfaces.
Provides instructions for programming minimum data for operation.
Details the magnetic keypad functions and how to use them.
Steps to set system units, pressure units, and atmospheric pressure.
Configuration of volumetric flow rate and time units.
Configuration of mass flow units, time, and decimal digits.
Steps to activate a channel and select measurement methods.
Inputting transducer and pipe data for accurate measurements.
Setting up path length, axial length, fluid type, and soundspeed.
Visual representation of the XGF868i initial setup menu flow.
Overview of topics for preparing the meter for operation.
Instructions on powering the device and initial system checks.
Describes the components and information shown on the LCD display.
Details the PanaView text display and its information content.
Guides on using LCD or PanaView for obtaining flow rate data.
Steps to configure parameters displayed on the LCD.
Steps to initiate and configure PanaView for data display.
Instructions for pausing and resuming measurements via PanaView.
Details on fluid types, pipe materials, and pipe sizes.
Specifies accuracy ranges for high and low flow velocities.
Accuracy specifications for molecular weight and mass flow.
Covers flow measurement mode, enclosures, dimensions, and weight.
Details temperature and pressure ranges, materials, and connections.
Physical characteristics and gain settings of the preamplifier.
Details standard and optional transducer cable types and lengths.
States requirements for CE Mark compliance in EU countries.
Details cable types and grounding for CE compliance.
Lists available option cards and their slot configurations.
Table for recording general, channel, and system setup data.
Explains the importance of path and axial length for flow measurement.
Provides methods and formulas for measuring P and L.
Details the warranty period and exclusions for materials and workmanship.
Procedure for returning malfunctioning instruments for service or repair.
Provides contact details for US and Ireland support centers.
Lists requirements for installing apparatus in hazardous areas per IEC standards.
Summarizes safety requirements, certifications, and markings for transmitters.
Manufacturer's declaration of conformity to relevant EU directives and standards.