117
Aquarea air-to-water heat pumps - Planning and installation manual - 02/2022
Planning
5
Bi-bloc systems with All in One unit
Models Power supply 1 Power supply 2
Phases Max. current
consumption
(A)
Max. power
consumption
(kW)
Min. cable size
(mm²)
Phases Max. current
consumption
(A)
Max. power
consumption
(kW)
Min. cable size
(mm²)
WH-ADC0309J3E5(B/C) +
WH-UD03JE5
1 12.0 2.59 3 x 1.5 1 13.0 3.0 3 x 1.5
WH-ADC0309J3E5(B/C) +
WH-UD05JE5
1 12.0 2.59 3 x 1.5 1 13.0 3.0 3 x 1.5
WH-ADC0309J3E5(B/C) +
WH-UD07JE5
1 15.9 3.47 3 x 2.5 1 13.0 3.0 3 x 1.5
WH-ADC0309J3E5(B/C) +
WH-UD09JE5-1
1 15.9 3.47 3 x 2.5 1 13.0 3.0 3 x 1.5
WH-ADC1216H6E5 +
WH-UD12HE5
1 24.0 5.30 3 x 4.0 1 26.0 6.0 3 x 4.0
WH-ADC1216H6E5 +
WH-UD16HE5
1 26.0 5.74 3 x 4.0 1 26.0 6.0 3 x 4.0
WH-ADC1216H6E5 +
WH-UX09HE5
1 29.0 6.27 3 x 4.0 1 26.0 6.0 3 x 4.0
WH-ADC1216H6E5 +
WH-UX12HE5
1 29.0 6.27 3 x 4.0 1 26.0 6.0 3 x 4.0
WH-ADC1216H6E5C +
WH-UD12HE5
1 24.0 5.30 3 x 2.5 1 26.0 6.0 3 x 4.0
WH-ADC1216H6E5C +
WH-UD16HE5
1 26.0 5.74 3 x 4.0 1 26.0 6.0 3 x 4.0
WH-ADC1216H6E5C +
WH-UX09HE5
1 29.0 6.27 3 x 4.0 1 26.0 6.0 3 x 4.0
WH-ADC1216H6E5C +
WH-UX12HE5
1 29.0 6.27 3 x 4.0 1 26.0 6.0 3 x 4.0
RCCB and power supplies Indoor unit / outdoor unit connection
L N
L N
L
1
N
1
L
1
N
1
1 2
3
1 2
3
3
3
r
L N
L N
L
1
N
1
L
1
N
1
1 2
3
1 2
3
3
3
r
RCCB
Power supplies
L N
L N
L
1
N
1
L
1
N
1
1 2
3
1 2
3
3
3
r
Power supply 1 Power supply 2
2
3
Terminal block
Indoor unit / outdoor unit
L N
L N
L
1
N
1
L
1
N
1
1 2
3
1 2
3
3
3
r
Connection of indoor unit
and outdoor unit
L N
L N
L
1
N
1
L
1
N
1
1 2
3
1 2
3
3
3
r
1
2
Terminals on indoor unit
Terminals on outdoor unit
Terminals on disconnector of the power supply
1
2
3

Table of Contents

Related product manuals