How to use electronic circuit diagram
TIMER TABLE
Test mode
Name Time (When test point Remarks
Short-circuited)
Sleep Mode Waiting 1 hr. 6 sec.
Sleep Mode Operation 8 hrs. 48 sec.
Real Timer 1 hr. 1 min.
10 min. 10 sec.
1 min. 1 sec.
Time Delay Safety Control 2 min. 58 sec. 0 sec.
Forced Operation 60 sec. 0 sec.
Time Save Control (Cooling) 7 min. 42 sec.
Anti-Freezing 4 min. 0 sec.
Soft Dry OFF 6 min. 36 sec.
ON 10 min. 60 sec. SOFT DRY : 10 min. operation
Deodorizing Control
40 sec. 4 sec.
Cooling 70 sec. 7 sec.
20 sec. 2 sec.
180 sec. 18 sec.
Soft Dry 40 sec. 4 sec.
360 sec. 36 sec.
Comp. Reverse Rotation Detection 5 min. 30 sec. Comp. ON 5 min. and above
2 min 0 sec.
Comp./ Fan Motor Delay Timer 1.6 sec. 0 sec.
Intake Air Anti-Freezing Prevention 16 min. 96 sec.
POWERFUL MODE 15 min. 4.5 sec.
Random Auto Restart Control 0 ~ 150 sec. 0 sec.
TRS Recovery Detection 12 min. 72 sec.
6 min. 36 sec.
3 min. 18 sec.
1 min. 6 sec.
Time Save Control (Heating) 30 min. 3 sec.
4 Way Valve Control (Delay) 5 min. 30 sec.
Deice Operation Occurs 60 min. 6 sec. 60 min. after previous deice
Deice Ends 12 min. 72 sec.
94