EasyManua.ls Logo

Panasonic CS-A24BD3P - Installation and Maintenance Features

Panasonic CS-A24BD3P
167 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
30 m of pipe length. This makes installation much easier.
2.3.3. Drain water dripping-prevention structure
- The base of the outdoor unit is provided with a single drain hole in
order to prevent drain water from leaking out of the unit. Body
connecting a drain elbow and a discharge pipe, water leakages
can be prevented even when the unit is installed against a wall.
2.3.4. Space saving design allows units to be installed side by side continuously
- Servicing after installation can be carried out by removing the front
covers.
2.3.5. Easy test operation
- Test operation can be carried out for both indoor and outdoor
units.
2.3.6. Long pipe design
Max piping length: 50 (m)
24BB~50BB
Height difference/
equivalent pipe length
30/50
2.3.7. Internal pipe connection
- Pipes are connected inside the units (inside the side covers),
making the final appearance more attractive.
- Pipes can be diverted outward in any of four directions (forward,
right, down, rear).
- Small liquid pipe diameters of 9.52mm for 43BB and 50BB models,