EasyManua.ls Logo

Panasonic CS-A24BD3P

Panasonic CS-A24BD3P
167 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
ORDER NO. MAC0111069C0
AIR CONDITIONER
HIDE AWAY TYPE
HEAT PUMP MODEL
CS-A24BD3P (CU-A24BBP5)
CS-A28BD3P (CU-A28BBP5, CU-A28BBP8)
CS-A34BD3P (CU-A34BBP5, CU-A34BBP8)
CS-A43BD3P (CU-A43BBP8)
CS-A50BD3P (CU-A50BBP8)
COOLING ONLY MODEL
CS-A24BD3P (CU-C24BBP5)
CS-A28BD3P (CU-C28BBP5, CU-C28BBP8)
CS-A34BD3P (CU-C34BBP5, CU-C34BBP8)
CS-A43BD3P (CU-C43BBP8)
CS-A50BD3P (CU-C50BBP8)
2001 Matsushita Air-Conditioning Corp. Sdn. Bhd. (183914D).
All rights reserved. Unauthorized copying and distribution is a
violation of law.
Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-A24BD3P and is the answer not in the manual?

Panasonic CS-A24BD3P Specifications

General IconGeneral
BrandPanasonic
ModelCS-A24BD3P
CategoryAir Conditioner
LanguageEnglish

Summary

Service Information and Features

Notice of Address Setting

Details on setting addresses for new cassette/outdoor units.

Trouble at Test Operation

Examples of issues that may indicate wrong address setting.

Cautions for Test Operation

Warnings regarding remote control and wiring during test operation.

Cautions for Automatic Address Setting

Precautions for automatic address setting to ensure proper system memorization.

Variety of Excellent Features

Overview of the product's diverse and advantageous features.

Compact Design and Versatile Installation

Highlights the unit's space-saving height and flexible installation options.

Easy Maintenance and Static Pressure Selection

Discusses ease of maintenance and selectable static pressure options.

Quiet Operation and Auto Fan Mode

Details on low noise levels and automatic fan speed adjustment.

Dry Mode and Automatic Changeover

Explains the dry mode function and automatic switching between heating/cooling.

Common Design and Wired Remote Control

Notes on common design for indoor units/remotes and wired remote control features.

New Low-Noise Outdoor Units

Introduction to the improved low-noise outdoor unit design.

Low-Noise Design Improvements

Details on specific design elements contributing to reduced noise.

Automatic Restart and Low Ambient Cooling

Features like automatic restart after power failure and low ambient cooling.

Improved Workability and System Renewal

Enhanced workability for system renewal, including pipe compatibility.

Installation and Maintenance Features

Covers drain water prevention, space-saving, easy testing, and pipe connections.

Centralized Draining and Advanced Control

Discusses centralized draining and new control methods for easier wiring.

Twin and Triple Operation Capabilities

Details on simultaneous air conditioning for multiple units.

Specifications

Heat Pump Model Specifications

Technical data for heat pump models, including CS-A24BD3P/CU-A24BBP5.

Cooling Only Model Specifications

Technical data for cooling-only models, including CS-A24BD3P/CU-C24BBP5.

Technical Drawing and Circuit Diagrams

Outside Dimensions Drawings

Visual representations of the unit's external dimensions.

Circuit Diagrams for Indoor and Outdoor Units

Electrical schematics for various unit configurations.

Operating Instructions and Controls

Wired Remote Control Operation

Explanation of the wired remote control's functions and part names.

Refrigeration Cycle Diagrams

Diagrams and explanations of the refrigeration cycles for heating and cooling models.

Operation Range and Power Supply

Details on applicable voltage and power supply ranges for different models.

Pipe Length Considerations

How pipe length affects capacities, refrigerant charge, and installation.

Operating Characteristics and Fan Performance

Performance data for heat pump and cooling-only models, including fan curves.

Safety Devices Overview

Details on safety devices for indoor and outdoor units.

Component Specifications

Detailed specifications for compressors, condensers, and fan motors.

Capacity and Power Consumption Data

Cooling and heating capacity/power consumption curves and rated data.

Discharge and Suction Pressure

Charts showing saturation temperatures at different pressure points.

Position of Centre of Gravity

Data detailing the center of gravity coordinates for various outdoor unit models.

Sound Data

Graphs showing sound pressure levels across different frequencies and fan speeds.

Twin and Triple System Operations

Procedures for setup, control, piping, refrigerant charging, and wiring.

Wiring Mistake Prevention

Explanation of a circuit that prevents wiring errors during installation.

Test Operation and Self Diagnosis

Detailed steps for performing test operations and interpreting self-diagnosis codes.

Energy Save and Thermistor Switch Settings

Instructions for configuring the energy-saving function and thermistor settings.

Group Control Procedures

Procedures for setting up and managing group control for multiple units.

Troubleshooting Common Issues

Common problems, symptoms, and solutions for installation and operation issues.

Emergency Operation Procedures

Steps for initiating emergency operation and checking thermistor values.

Control Functions Overview

Details on cooling/heating modes, defrosting, thermostat, fan control, and other operations.

Installation Procedures

Indoor Unit Installation

Instructions for installing the indoor unit, including PCB layout.

Outdoor Unit Installation

Safety precautions and guidelines for installing the outdoor unit.

Replacement Parts

Indoor Unit Replacement Parts

A list of part numbers and quantities for indoor unit components.

Outdoor Unit Replacement Parts

A list of part numbers and quantities for outdoor unit components.

Related product manuals