1. Cooling capacities are based on indoor temp. 27°C D.B (80.6°F
D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air temp. 35°C D.B.
(95°F D.B.), 24°C W.B. (75.2°F W.B.)
2. Heating capacities are based on indoor temp. 20° CD.B (68.0°
FD.B.) and outdoor air temp. 7°C D.B. (44.6°F D.B.), 6°C W.B.
(42.8°F D.B.)
ELECTRICAL DATA (50Hz)
MODEL / ITEM
CS-A50BD3P/CU-A50BBP8
Condition by JIS B 8616
Volts V 380 400 415
Phase 3N 3N 3N
Input Power kW Cool 5.10 5.10 5.10
Heat 5.09 5.09 5.09
Running Current A Cool 8.8 8.8 8.8
Heat 8.8 8.8 8.8
Starting Current A 69 69 69
Power Factor % Cool 88 84 81
Heat 88 83 80
*Power Factor means total figure of compressor, indoor fan motor and outdoor fan motor.
Panasonic Power
source
AC, 3N~380V, 400V, 415V 50Hz
4. SPECIFICATION (COOLING ONLY TYPE )
4.1 CS-A24BD3P / CU-C24BBP5