Model
Name
Standard piping specification
Liquid
piping
(dia.mm)
Gas
piping
(dia.mm)
Gas
charge-
less
length
(m)
Additional
gas
volume (g/
m)
CU-
A24BBP5
6.35 15.88 30 20
CU-
A28BBP5
9.52 15.88 30 50
CU-
A28BBP8
9.52 15.88 30 50
CU-
A34BBP5
9.52 19.05 30 50
CU-
A34BBP8
9.52 19.05 30 50
CU-
A43BBP8
9.52 19.05 30 50
CU-
A50BBP8
9.52 19.05 30 50
Model
Name
Existing piping specification (Larger
piping)
Liquid
piping
(dia.mm)
Gas
piping
(dia.mm)
Gas
charge-
less
length
(m)
Addition
gas
volume (g/
m)
CU-
A24BBP5
9.52 15.88 13 50
CU-
A28BBP5
12.7 15.88 17 100
CU-
A28BBP8
12.7 15.88 17 100
CU-
A34BBP5
12.7 19.05 17 100
CU-
A34BBP8
12.7 19.05 17 100
CU-
A43BBP8
12.7 19.05 17 100
CU-
A50BBP8
12.7 19.05 17 100
2. Piping installation by existing piping
The above models change the liquid pipe size of the previous
69

Other manuals for Panasonic CS-A28BB4P

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-A28BB4P and is the answer not in the manual?

Panasonic CS-A28BB4P Specifications

General IconGeneral
BrandPanasonic
ModelCS-A28BB4P
CategoryAir Conditioner
LanguageEnglish

Related product manuals