Outdoor Unit
To protect compressor from reverse
rotation when there is a instantaneous
power failure.
60 Secs. Forced Operation Control
Once the compressor is activated, it
does not stop within the first 60 secs.
However, it stops immediately with
remote control stop signal.
Overload Protector
Inner protector.
Compressor Reverse Rotation
Protection Control
Outdoor Fan Operation Control
C24CK
6-pole induction motor (2 speed).
For Cooling or Soft Dry operation
Hi-speed ............. When outdoor
temperature reaches to 31°C.
Lo-speed ............. When outdoor
temperature reaches to 29°C.
C18CK
6-pole induction motor (1 speed).
5
CS-C18CKR CU-C18CKR / CS-C24CKR CU-C24CKR