32
2. Norrowing
Vertical Airflow Direction
During dew prevention control, Airflow Direction Auto-control angle change from 10° - 38° to 10° - 27° under
Cooling and Soft Dry operation mode.
During dew prevention control, Airflow Direction Manual control angle change from 10°, 14°, 18°, 22°, 27° to
10°, 13°, 16°, 19°, 22° under Cooling and Soft Dry operation mode.
3. Narrowing
Horizontal Airflow Direction
During dew prevention control, Airflow Direction Auto-control angle change form 0° - 44° to 14° - 30° under
Cooling and Soft Dry operation mode.
During dew prevention control, Airflow Direction Manual control angle change from 0°, 11°, 22°, 33°, 44° to
14°, 18°, 22°, 26°, 30° under Cooling and Soft Dry operation mode.