5
2 Specifications
2.1. CS-C18GKV CU-C18GKV
1. Cooling capacities are based on indoor temperature of 27°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air
temperature of 35°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
Item Unit Indoor unit Outdoor unit
Performance Test Condition NEW JIS
Capacity kW 5.30
BTU/h 18100
*kJ/h —
EER W/W 3.08
BTU/hW 10.52
Noise Level dB (A) High: 42 Low: 37 High: 54 / -
Power level dB — —
Moisture Removal l/h 2.9
(pt/h) 6.1
Air Volume Lo
m
3
/m (ft
3
/m)
12.5 (442) —
Me
m
3
/m (ft
3
/m)
13.6 (480) —
Hi
m
3
/m (ft
3
/m)
14.8 (520) 51.0 (1800)
SHi
m
3
/m (ft
3
/m)
15.5 (545) —
Refrigerant Control Device — Capillary Tube
Refrigerant Oil (Charged)
cm
3
— ATMOS M60 or
ATMOS 56M or
SUNISO 4GDID (650cm
3
)
Refrigerant (Charged) R22 kg (oz) — 1.33 (46.9)
Dimension Height mm (inch) 275 (10 - 13/16) 750 (29 - 17/32)
Width mm (inch) 998 (39 - 9/32) 875 (34 - 7/16)
Depth mm (inch) 230 (9 - 1/16) 345 (13 - 19/32)
Net Weight kg (lbs) 11 (24) 48 (106)
Pipe Diameter Gas mm (inch) 12.70 (1/2”)
Liquid mm (inch) 6.35 (1/4”)
Height Difference m (ft) 20 (65.6)
Pipe Length Range m (ft) 3 (9.8) - 25 (82.0)
Additional Gas Amount g/m (oz/ft) 20 (0.2)
Refrigeration Charge Less m (ft) 7.5 (24.6)
Drain Hose Inner diameter mm 16 —
Length mm 650 —
Compressor Type — Rotary (1 cylinder)
rolling piston type
Motor Type — Induction (2-poles)
Rated Output W — 1.2k
Fan Type Cross-flow Fan Propeller Fan
Material ASHT-18 PP Resin
Motor Type Transistor (8-poles) Induction (6-poles)
Input power W 47.3 162.8
Output power W 30 69
Fan Speed Lo (Cool) rpm 1150 —
Me (Cool) rpm 1250 —
Hi (Cool) rpm 1360 870
SHi (Cool) rpm 1420 —
Heat Exchanger Fin material Aluminium (Pre Coat) Aluminium (Gold Coat)
Fin Type Slit Fin Louver Fin
Row × Stage × FPI 2 × 15 × 21 2 × 34 × 16
Size (W × H × L) mm 810 × 315 × 25.4 814.8:834.8 × 714 × 25.4
Air Filter Type Material Polypropelene —
Style One-touch —