40
Airflow direction (Horizontal, Vertical) Control
o During any operation mode combines with Patrol operation, airflow direction follows respective operation
mode.
o During Patrol individual operation if e-ion starts, only Auto Air Swing is allowed. Even if “Air Swing” button is
pressed, no signal is sent to air conditioner, and no change on LCD display.
o During Patrol individual operation if e-ion stops, Airflow direction louver closed.
LED display (Applicable to all models except KKD models)
o When Patrol operation is selected, Patrol LED illuminates.
o During Patrol individual operation, only Patrol LED illuminates. When e-ion air purifying operation starts
based on dirtiness level, Power LED, Patrol LED and e-ion LED illuminates.
PATROL LED E-ION TIMER
No Description BLUE ORANGE RED BLUE ORANGE
1 When patrol function is not selected OFF OFF OFF - -
2 During gas sensor error detection control OFF OFF Blinking OFF OFF
3 During E-ion abnormal discharge error OFF OFF OFF Blinking OFF
4 During E-ion breakdown error OFF OFF OFF Blinking Blinking
5 During Test Mode OFF OFF OFF OFF OFF
6 During stop OFF OFF OFF OFF OFF
7 2 minutes gas sensor initial stabilization time (Level 0) ON OFF OFF OFF OFF
a. Dirtiness level 0* ON OFF OFF OFF OFF
b. Dirtiness level 1 OFF ON OFF OFF OFF
c. Dirtiness level 1* OFF ON OFF ON OFF
8
During operation
During patrol
d. Dirtiness level 2 OFF OFF ON ON OFF
Remote Control Receiving Sound
o Normal Operation Î Patrol Mode : Beep
o Patrol Mode Î Stop : Long Beep
o Patrol Mode Î Normal Operation : Beep
o Stop Î Patrol : Beep
Timer Control
o When ON timer activates when unit stops, previous operation resumes and restored last saved Patrol
operation status.
o When ON timer activates during any operation, no change and carry on current operation.
o When OFF timer activates during any operation, all operation stops and the latest Patrol operation status is
saved.
Power Failure Control
o During Patrol individual operation, if power failure occurs, after power resumes, Patrol individual operation
resumes immediately.
o During combination operation, if power failure occurs, after power resumes combination operation resume
immediately.