18
How to Fix Installation Plate
To Drill a Hole in the wall and install a sleeve of piping
Installation instructions
Indoor Unit
The mounting wall shall be strong and solid enough to prevent it from vibration.
Model
Dimension
HU12 Series, XU12 Series, 
AU12 Series
HU18 Series, XU18 Series, 
AU18 Series, AU24 Series.
490 mm
590 mm
82 mm
82 mm
439 mm
539 mm
432 mm
532 mm
43 mm
169 mm
95 mm
219 mm
3
4
5
6
Wall
Wall
Wall
Installation plate 
 screw
More than 
More than 
Indoor unit
241.5 mm
128 mm
241.5 mm
128 mm
128 mm
More than 
For best strength of INDOOR 
unit installation, it is highly 
recommended to locate “
” 
at 5 position as shown.
Measuring 
Tape
The center of installation plate should be at more than       at right and left of the wall.
The distance from installation plate edge to ceiling should more than      .
From installation plate center to unit’s left side is      .
From installation plate center to unit’s right side is      .
        :   For left side piping, piping connection for liquid should be about       from this line.
        :   For left side piping, piping connection for gas should be about       from this line.
        1   Mount the installation plate on the wall with 5 screws or more (at least 5 screws).
             (If mounting the unit on the concrete wall, consider using anchor bolts).
              •   Always mount the installation plate horizontally by aligning the marking-off line with the thread and using
   a level gauge. 
        2   Drill the piping plate hole with ø70 mm hole-core drill.
              •   Line according to the left and right side of the installation plate. 
                  The meeting point of the extended line is the center of the hole. 
                  Another method is by putting measuring tape at position as shown in the diagram above.
  The hole center is obtained by measuring the distance namely 128 mm for left and right hole respectively.
              •  Drill the piping hole at either the right or the left and the hole should be slightly slanting to the outdoor side.
①
②
③
④
○
B
⑤
⑥
1  Insert the piping sleeve to the hole.
2  Fix the bushing to the sleeve.
3  Cut the sleeve until it extrudes 
    about 15 mm from the wall.
4  Finish by sealing the sleeve with putty 
    or caulking compound at the final stage.      
15 mm
Putty or caulking 
compound
ø70 mm 
through 
hole
Indoor
Outdoor
Sleeve 
for tube 
assembly
Approx.
5 - 7 mm
Bushing 
for tube 
assembly
Wall
CAUTION
 
When the wall is hollow, please be 
sure to use the sleeve for tube 
assembly to prevent dangers caused
by mice biting the connection cable.