Connect the Cable to the Indoor Unit
The power supply cord, indoor and outdoor unit connection cable can be connected without removing the front grille.
       Install the indoor unit on the installing holder that mounted on the wall.
       Open the front panel and grille door by loosening the screw.
       Cable connection to the power supply through Isolating Devices (Disconnecting means).
  •  Connect the approved polychloroprene sheathed power supply cord  3 x 1.5 mm
2
  (1.5 ~ 2.0 HP) or 
      3 x 2.5 mm
2
  (2.5HP), type designation IS 694 or 60245 IEC 57 or heavier cord to the terminal board, 
      and connect the other end of the cable to Isolating Devices (Disconnecting means). 
  •  Do not use joint power supply cord. Replace the wire if the existing wire (from concealed wiring, or 
      otherwise) is too short.
  •  In unavoidable case, joining of power supply cord between isolating devices and terminal board of 
     air conditioner shall be done  by using approved socket and plug rated 15/16A (1.5HP) or 16A (2.0HP)
     or 20A (2.5HP). Wiring work to both socket and plug must follow to national wiring standard.
       Bind all the power supply cord lead wire with tape and route the power supply cord via the left escapement.
       Connection cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed 
       4 x 1.0 mm
2
 (1.5 ~ 1.8HP), 4 x 1.5 mm
2
 (2.0HP) or 4 x 2.5mm
2
 (2.5HP) flexible cord, type designation
       IS 694 or 60245 IEC 57 or heavier cord.
       Bind all the indoor and outdoor connection cable with tape and route the connection cable via the right 
       escapement.
       Remove the tapes and connect the power supply cord and connection cable between indoor unit and outdoor
       unit according to the diagram below.  
t
i
nuro
odtuoe
htnoslani
mre
T
Colour of wires (connection cable)
Terminals on the indoor unit
(Power supply cord)
Terminals on the isolating 
devices (Disconnecting means)
32
1
LN123
(L) (N)
Note:
•  Isolating Devices (Disconnecting means) should have minimum 3.0 mm contact gap.
•  Ensure the colour of wires of outdoor unit and the terminal Nos. are the same to the indoor’s respectively.
•  Earth wire shall be Yellow/Green (Y/G) in colour and longer than other AC wires as shown in the figure for the 
    electrical safety in case of the slipping out of the cord from the anchorage.   
Recommended 
length (mm)
abcdefg
55 35 35 50 40 35 60
Connection cable
Power 
supply 
cord
Terminal Board
Control 
Board
Recommended length (mm)
Earth Wire 
longer than 
others AC 
wires for 
safety reason
Earth Wire 
longer 
than 
others 
AC wires 
for safety 
reason
Holder
Holder
Indoor & outdoor 
connection cable
Power supply 
cord
Outdoor unitIsolating Devices
Tape
Tape
 WARNING
This equipment must be properly earthed. 
21