BEE Regulation
Turn on the unit.
Testing Guidelines
Cooling Test Mode for Full Load (100%) and
Half Load (50%)
1) Mode : Select ‘COOL’
2) Temperature : a) 16 ºC for Full Load (100%)
3) Air Swing
Vertical Airflow
: Set vane position to 3rd step
from top
: b) 17 ºC for Half Load (50%)
(For Full Load)
Open the Front Panel by lifting Intake Grille.
Follow the below Instructions.
Step a): Press and Hold the (Auto OFF/ON) button
on indoor Unit.
Control button, while holding the
indoor unit button.
Step b): Within 5 second, press once the Remote
Step c): After hearing a beep sound from the Indoor
Unit, immediately release the (Auto OFF/ON)
button on Indoor Unit.
All this should be done within 5 seconds.
4) Air Swing
Horizontal Airflow
:
Set vane position to be
straight
(For applicable Model)
5) Fan speed :
Maximum
(For Half Load)
1
2
1
2
1
2
1
2
(Auto OFF/ON Button)
(Indication for Half load)
(Indication for Full load)
Indoor unit Temperature Display will show “ ” for Full Load and “ ” for Half Load Setting.
English BEE Regulation