Performance Test Condition ARI
Power Supply
Phase, Hz Single, 60
V 208 230
Min. Mid. Max. Min. Mid. Max.
Cooling
Capacity
kW 1.20 3.36 3.90 1.20 3.36 3.90
BTU/h 4100 11500 13300 4100 4100 13300
Running Current A - 4.7 - - 4.2 -
Input Power W 250 920 1.15k 250 920 1.15k
EER
W/W 4.80 3.64 3.39 4.80 3.64 3.39
BTU/hW 16.40 12.50 11.55 16.40 12.50 11.55
Power Factor % - 94 - - 95 -
Indoor Noise (H / L / QLo)
dB-A 35 / 28 / 25 35 / 28 / 25
Power Level dB 51 / - / - 51 / - / -
Outdoor Noise (H / L / QLo)
dB-A 49 / - / - 49 / - / -
Power Level dB 64 / - / - 64 / - / -
Heating
Capacity
kW 1.20 4.05 4.77 1.20 4.05 4.77
BTU/h 4100 13800 16300 4100 13800 16300
Running Current A - 6.3 - - 5.6 -
Input Power W 200 1.25k 1.71k 200 1.25k 1.71k
COP
W/W 6.00 3.24 2.79 6.00 3.24 2.79
BTU/hW 20.50 11.00 9.50 20.50 11.00 9.50
Power Factor % - 95 - - 97 -
Indoor Noise (H / L / QLo)
dB-A 35 / 28 / 25 35 / 28 / 25
Power Level dB 51 / - / - 51 / - / -
Outdoor Noise (H / L / QLo)
dB-A 51 / - / - 51 / - / -
Power Level dB 66 / - / - 66 / - / -
Min Circuit Ampacity 15.00
Max. Overcurrent Protection 15.00
Max Current (A) / Max Input Power (W) 7.8 / 1.71k
Starting Current (A) 6.30
SEER/HSPF 20.00 / 10.00