F566080
QUICK GUIDE / GUÍA RÁPIDA
QUICK GUIDE / GUÍA RÁPIDA
GUIDA RAPIDA / KURZANLEITUNG
GUIDA RAPIDA / KURZANLEITUNG
GUΙA RÁPIDO / SNELLE GIDS
GUΙA RÁPIDO / SNELLE GIDS
© 2008 Panasonic HA Air-Conditioning (M) Sdn. Bhd.
(11969-T). All rights reserved. Unauthorized copying
and distribution is a violation of law.
ENGLISH 2 ~ 11
Before operating the unit, read these operating
instructions thoroughly and keep them for future
reference.
ESPAÑOL 12 ~ 21
Antes de utilizar la unidad, sírvase leer atentamente
estas instrucciones de funcionamiento y conservarlas
como futuro elemento de consulta.
ITALIANO 22 ~ 31
Prima di utilizzare l’unità si prega di leggere
attentamente le istruzioni e di conservare questo
opuscolo per potervi fare riferimento in futuro.
DEUTSCH 32 ~ 41
Bevor Sie das Gerät in Betrieb nehmen, lesen Sie bitte
diese Bedienungsanleitung aufmerksam durch und
bewahren Sie sie für die künftige Verwendung auf.
PORTUGUÊS 42 ~ 51
Antes de ligar a unidade, leia cuidadosamente
este manual de utilização e guarde-o para futura
referência.
NEDERLANDS 52 ~ 61
Lees voor u het apparaat gebruikt deze
gebruiksinstructies grondig en bewaar ze voor
toekomstig gebruik.
Operating Instructions
Air Conditioner
Indoor Unit
CS-F18DTE5 CS-F34DTE5
CS-F24DTE5 CS-F43DTE5
CS-F28DTE5 CS-F50DTE5
Outdoor Unit
Inverter Model
(HBE5 Series) (DBE5, DBE8 Series)
CU-YL24HBE5 CU-L24DBE5
CU-YL28HBE5 CU-L28DBE5
CU-YL34HBE5 CU-L34DBE5
CU-YL43HBE5 CU-L43DBE5
(GBE5 Series) CU-L34DBE8
CU-YL24GBE5 CU-L43DBE8
CU-YL28GBE5 CU-L50DBE8
CU-YL34GBE5
CU-YL43GBE5
Heat-pump Model
CU-B18DBE5 CU-B28DBE8
CU-B24DBE5 CU-B34DBE8
CU-B28DBE5 CU-B43DBE8
CU-B34DBE5 CU-B50DBE8
Cooling Model
CU-J18DBE5 CU-J24DBE8
CU-J24DBE5 CU-J28DBE8
CU-J28DBE5 CU-J34DBE8
CU-J34DBE5 CU-J43DBE8
CU-J50DBE8

Other manuals for Panasonic CS-F50DTE5

Questions and Answers

  • R
    Randall FlemingAug 15, 2025
    Why is my Panasonic Air Conditioner showing an indoor/outdoor unit disconnection problem?
    • U
      ufarrellAug 16, 2025
      The issue might stem from a disconnection between the indoor and outdoor units, which can be caused by problems with the connection cable and terminals. Check the power supplies on both the indoor and outdoor units. Alternatively, there could be a general connection error between the units.
  • M
    martinezsandraAug 18, 2025
    How to fix a system problem on my Panasonic CS-F50DTE5 (F30 error)?
    • M
      mollygreeneAug 18, 2025
      The system problem could arise from an insufficient total capacity for the number of indoor units. To resolve this, verify the total capacity against the number of indoor units. Also, check for an open or reversed phase in the power supply. Inspect the main power supply terminal board connections, and if necessary, switch over any two of the power supply wires.
  • B
    Brittany VincentAug 21, 2025
    What causes the F20 error on my Panasonic CS-F50DTE5 Air Conditioner?
    • F
      Frederick WeberAug 21, 2025
      The error indicates a problem with the indoor temperature sensor. Check the indoor temperature sensor lead wire, the indoor unit connector, or CN-TH2. It could also be a remote control thermistor problem.
  • W
    welchjamesAug 25, 2025
    What does inverter protection (Low DC voltage) mean for my Panasonic CS-F50DTE5?
    • T
      tonygriffinAug 26, 2025
      This could be due to a low DC voltage, in which case you should check the power supply. Alternatively, it might be an IPM (Intelligent Power Module) protection issue, indicating an IPM fault or a problem with the main PCB (Printed Circuit Board).
  • M
    Molly HuntAug 27, 2025
    Why is my Panasonic CS-F50DTE5 Air Conditioner displaying a pipe temp sensor problem?
    • J
      Jennifer McdonaldAug 27, 2025
      The issue stems from a problem with the pipe temperature sensor in the indoor unit. Inspect the pipe temperature sensor lead wire or the indoor unit connector CN-TH1.
  • C
    Crystal RobinsonAug 31, 2025
    How to troubleshoot a drain level float switch problem in Panasonic Air Conditioner?
    • B
      Brian MontesAug 31, 2025
      The problem is related to the drain level float switch. Inspect the drain pump and drain pipe, as well as the indoor unit connectors CN-DRMTR and CN-TH2.
  • S
    Sarah HillSep 2, 2025
    What to do if my Panasonic CS-F50DTE5 Air Conditioner has a remote control transmission problem?
    • M
      Mr. Joseph Kelly DDSSep 3, 2025
      This indicates an issue with the remote control transmission. Verify the remote control unit cable and connection terminals.
  • J
    Jennifer MarshallSep 5, 2025
    What does D. C Fan motor lock problem mean for my Panasonic CS-F50DTE5 Air Conditioner?
    • T
      Todd GomezSep 6, 2025
      The issue is related to the D. C Fan motor being locked. Check the D. C Fan motor lock.
  • B
    Brandon JensenSep 9, 2025
    What causes a louver switch problem in a Panasonic CS-F50DTE5?
    • M
      Michael MoranSep 9, 2025
      The problem lies with the louver switch. Check the louver motor, the decorative panel connection terminal, or the indoor unit louver motor connectors.
  • D
    Debra GeorgeSep 12, 2025
    What should I do if my Panasonic Air Conditioner displays a D. C Fan Motor problem?
    • S
      Scott LawrenceSep 12, 2025
      The error indicates a problem with the D. C Fan Motor. Check the indoor unit D. C Fan motor or its connection terminals.

Summary

Safety Precautions

Wireless Remote Control Safety

Safety advice and precautions for using the wireless remote control.

Power Supply Safety

Essential safety guidelines related to the unit's power supply.

Indoor Unit Safety

Important safety warnings and prohibitions for the indoor unit.

Outdoor Unit Safety

Safety precautions and warnings specific to the outdoor unit.

Regulatory Information and Operation Conditions

Operation Condition Ranges

Specifies the indoor and outdoor temperature ranges for unit operation.

Collection and Disposal of Old Equipment

Guidance on proper disposal of used electrical products and batteries.

Product Overview and Operations (Wireless Remote Control)

Wireless Remote Control Layout

Overview and identification of components on the wireless remote control.

Remote Control Preparation

Instructions for inserting batteries and preparing the remote control.

Basic Operations

How to turn the unit on/off, set temperature, and select operation modes.

Advanced Wireless Features

Instructions for fan speed, airflow direction, economy mode, and odour removal.

Product Overview and Operations (Wired Remote Control)

Wired Remote Control Layout

Overview and identification of components on the wired remote control.

Wired Remote Control Preparation

Instructions for setting the day and time on the wired remote control.

Basic Wired Operations

How to turn the unit on/off, set temperature, and select operation modes.

Advanced Wired Features

Instructions for fan speed, airflow direction, economy mode, and odour removal.

Setting the Weekly Timer

Weekly Timer Operation Details

Explains functionality, daily vs. weekly timer, and timer program limits.

Timer Program Management

How to check, modify, add, or cancel timer programs.

Weekly Timer Control

Instructions to disable or enable previously set weekly timer programs.

Care and Cleaning

Washing Instructions and Hints

Guidelines for washing the unit and maintenance tips.

Air Filter Removal and Installation

Step-by-step guide for removing and installing air filters.

Air Filter Maintenance

Recommendations for cleaning air filters and resetting the indicator.

Troubleshooting

Normal Operation Phenomena

Symptoms that do not indicate a malfunction but are normal operations.

Pre-Servicing Checks

Checks to perform before calling for servicing or professional help.

Wired Remote CHECK Display

Interpreting and responding to the 'CHECK' indicator on the wired remote.

Extended Non-Use Procedures

Steps for seasonal inspection and preparing for extended non-use.

Non-Serviceable Criteria

Conditions requiring immediate power off and professional service.

Panasonic CS-F50DTE5 Specifications

General IconGeneral
Indoor unit typeCeiling
Indoor unit weight47000 g
Indoor units quantity1
Indoor unit dimensions (WxDxH)1600 x 700 x 250 mm
Indoor unit noise level (high speed)50 dB
Outdoor unit weight105000 g
Outdoor unit noise level56 dB
Outdoor unit dimensions (WxDxH)900 x 320 x 1340 mm
Hose length (max)50 m
Inverter technologyYes
Refrigerating mediumR410A
Cooling capacity (max)47700 BTU/h
Heating capacity (max)54600 BTU/h
Air conditioner functionsCooling, Heating
Cooling capacity in watts (max)14000 W
Heating capacity in watts (max)16000 W
Cooling energy efficiency (EER, W/W)2.91
Heating energy efficiency (COP, W/W)3.41