– 34 –
MAC9611041C2
CS-MC120KE
Technical Data
LL
LL
L Thermostat characteristics
CS-MC120KE
• Cooling
16
16
(°C)
Thermostat setting (remote control)
Intake Air Temperature
/
COMP. OFF = Set temperature
/
COMP. ON
18 28
2624
2220
30
18
20
22
24
26
28
30
32
34
(°C)
/
diff. 1.5°C
/
/
/
Cooling ON
/
/
diff. 1.5°C
16
16
(°C)
Intake Air Temperature
/
Soft Dry OFF
/
diff. 1.0°C
Thermostat setting (remote control)
34
24
22
20
18
28
26
30
32
18 20
22
24
26
28 30
/
/
Soft Dry ON
Cooling OFF = Set temperature,
LL
LL
L Operation characteristics
CS-MC120KE/CU-MC240KE
The capability value shown is the value for one unit. For a total for two unit, multiply by 2.
30 32 34 36 38 40 42 44
OUTDOOR AIR TEMPERATURE (°C)
[Condition] Room temperature: 27/19°C
Cooling operation: At High fan
Piping length: 5 m
8
7
6
5
14
13
12
11
10
0.65
0.60
0.55
0.50
0.45
3.8
3.6
3.4
3.2
3.0
2.8
220V
240V
I: Q:
Current (A) Cooling Capacity (kW)
LP: O: Outlet
Gas Side Piping Pressure (MPa) Air Temperature (°C)
O
Q
LP
I
• Cooling Characteristic • Piping Length Characteristic
1
5
10
15
PIPING LENGTH (m)
[Condition] Room temperature: 27/19°C
Outdoor temperature: 35/24°C
Cooling operation: At High fan
7
6
5
4
13
12
11
10
9
0.60
0.55
0.50
0.45
3.8
3.6
3.4
3.2
3.0
2.8
220V
240V
I: Q:
Current (A) Cooling Capacity (kW)
LP: O: Outlet
Gas Side Piping Pressure (MPa) Air Temperature (°C)
O
Q
LP
I
• Soft Dry
Untitled-7 6/30/00, 1:26 PM34